Application of Bioimpedance Spectroscopy in Asian Dialysis Patients (ABISAD): serial follow-up and dry weight evaluation

نویسندگان

  • Huan-Sheng Chen
  • Kuan-Chang Lee
  • Chun-Ting Cheng
  • Chun-Cheng Hou
  • Hung-Hsiang Liou
  • Chun-Ju Lin
  • Paik-Seong Lim
چکیده

BACKGROUND Maintenance of the optimal fluid status in hemodialysis patients is still a challenging task in daily clinical practice. A bioelectric impedance technique has been applied for evaluation of hydration status in the dialysis population in recent years, but serial observations of its role in clinical dry weight determination are lacking. In this study, serial follow-up data of a body composition monitor based on bioimpedance spectroscopy (BCM-BIS) applied in dialysis patients were analyzed to define the technique's feasibility, precision and possible role in dry weight determination. METHODS BCM-BIS was applied monthly to 194 hemodialysis patients for 6 months. Intra-patient precision was analyzed. Bland-Altman analysis and repeated-measures analysis of variance (ANOVA) were used to define the relationship between the dry weights determined by BCM-BIS and by clinical judgment. RESULTS The coefficients of variation (CVs) of fluid parameters were <5%. Serial changes in dry weight differences were compared in groups with different post-dialysis hydration status and dry weight differences decreased gradually. Bland-Altman analysis revealed that the range of these differences was significantly narrower towards the latter part of the study. The upper limit of agreement with 95% confidence interval (CI) was 1.47 L and the lower limit was -3.02 L. CONCLUSIONS BCM-BIS is precise and can be easily applied in the clinical setting. Discrepancy between the dry weights determined by BCM-BIS and by clinical judgment significantly decreased during the study. It is sensitive in dry weight determination, especially for those patients with obvious over-hydration (OH) by BCM-BIS. Patients with post-dialysis OH results beyond some critical values (>1.5 L or <-3 L) should be closely monitored.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of clinical dry weight assessment in haemodialysis patients using bioimpedance spectroscopy: a cross-sectional study.

BACKGROUND Dry weight assessment (DWA) is essential to efficient therapy of haemodialysis (HD) patients. However, so far objective methods for DWA have not been applicable to daily routine. Thus, exact fluid management in HD remains difficult and is often based on clinical criteria. The aims of this study were (1) to objectively define pre- and post-dialytic ranges of extracellular volume in a ...

متن کامل

Rationale and design of BISTRO: a randomized controlled trial to determine whether bioimpedance spectroscopy-guided fluid management maintains residual kidney function in incident haemodialysis patients

BACKGROUND Preserved residual kidney function (RKF) and normal fluid status are associated with better patient outcomes in incident haemodialysis patients. The objective of this trial is to determine whether using bioimpedance technology in prescribing the optimal post-dialysis weight can reduce the rate of decline of RKF and potentially improve patient outcomes. METHODS/DESIGN 516 pateints c...

متن کامل

Fluid status evaluation by inferior vena cava diameter and bioimpedance spectroscopy in pediatric chronic hemodialysis

BACKGROUND Evaluation of patient's dry weight remains challenging in chronic hemodialysis (HD) especially in children. Inferior Vena Cava (IVC) measurement was reported useful to assess fluid overload both in adults and children. METHODS We performed a monocentric prospective study to evaluate the relation between predialytic IVC diameter measurements and hydration status evaluated by physici...

متن کامل

Calf bioimpedance spectroscopy for determination of dry weight in hemodialysis patients: effects on hypertension and left ventricular hypertrophy.

BACKGROUND/AIMS Dry weight estimation in hemodialysis patients is still a substantial problem. Despite meticulous clinical assessment, fluid overload is common, leading to hypertension and left ventricular hypertrophy (LVH). Segmental calf bioimpedance spectroscopy (cBIS) is a novel tool for dry weight assessment. Here we tested the hypothesis, that its clinical routine use reduces arterial hyp...

متن کامل

An evaluation of blood volume changes during ultrafiltration pulses and natriuretic peptides in the assessment of dry weight in hemodialysis patients.

Changes in blood volume (BV) during dialysis as well as plasma levels of brain natriuretic peptide (BNP) and N-terminal (NT) pro-BNP levels are possible tools to assess dry weight in hemodialysis (HD) patients. The aim of the study was to compare these parameters with other non-invasive techniques used to assess dry weight in HD patients, and to study their relation with intradialytic hypotensi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2013