TG-21 versus TG-25: a comparison for electrons.

نویسندگان

  • D S Followill
  • D S Davis
  • W F Hanson
چکیده

Since 1984, the Radiological Physics Center (RPC) has used the American Association of Physicists in Medicine Task Group 21 (TG-21) protocol (absorbed dose determination) as the basis of its On-site Dosimetry Review visits to institutions participating in the National Cancer Institute's cooperative clinical trials. Subsequent to the TG-21 protocol, the Task Group 25 (TG-25) report on electron-beam dosimetry was published. The TG-25 report was not intended to supercede the TG-21 protocol, but to supplement it for depths other than dmax. However, both reports included measurement techniques and data regarding the calibration of electron beams. TG-25 was not intended for absolute calibrations made clear by the fact that it does not present all of the data required for plastic phantom calibrations, i.e., unrestricted stopping power ratios. As a result, some confusion has arisen at various institutions as to which protocol should be used for machine calibration. In this study, possible discrepancies that arise when using TG-21, a version of TG-21 modified by the RPC, and TG-25 are compared. The differences in the results are calculated as a function of energy (6 and 20 MeV), chamber type (cylindrical or parallel plate), and the type of phantom material (water, polystyrene, or acrylic). The largest discrepancies noted were between TG-25 and the two TG-21 methods for low-energy electrons in either water or polystyrene. The mean difference for all conditions was 0.8% with a maximum value of 3.3% in polystyrene. The definition of the effective point of measurement; determination of the mean nominal incident energy (E0), mean energy at depth (EZ) and most probable energy at the surface (Ep,0) for each protocol, and subsequent stopping power ratio, chamber replacement factor, and electron fluence correction factor are the major contributors to the calculated differences.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differences in electron beam dosimetry using two commercial ionization chambers and the TG‐21 protocol: Another reason to switch to TG‐51

Two of the most popular dosimetry systems used for calibration of megavoltage photon and electron beams in radiation therapy are (i) cylindrical Farmer-type chambers in liquid water and (ii) Holt Memorial parallel-plate chambers in clear polystyrene. Since implementation of the AAPM TG-21 calibration protocol, the Radiological Physics Center (which uses the Farmer in-water system) has compared ...

متن کامل

TG‐51: Experience from 150 institutions, common errors, and helpful hints

The Radiological Physics Center (RPC) is a resource to the medical physics community for assistance regarding dosimetry procedures. Since the publication of the AAPM TG-51 calibration protocol, the RPC has responded to numerous phone calls raising questions and describing areas in the protocol where physicists have had problems. At the beginning of the year 2000, the RPC requested that institut...

متن کامل

Comparison between TG‐51 and TG‐21: Calibration of photon and electron beams in water using cylindrical chambers

A new calibration protocol, developed by the AAPM Task Group 51 (TG-51) to replace the TG-21 protocol, is based on an absorbed-dose to water standard and calibration factor (N(D,w)), while the TG-21 protocol is based on an exposure (or air-kerma) standard and calibration factor (N(x)). Because of differences between these standards and the two protocols, the results of clinical reference dosime...

متن کامل

Oral 6-mercaptopurine versus oral 6-thioguanine and veno-occlusive disease in children with standard-risk acute lymphoblastic leukemia: report of the Children's Oncology Group CCG-1952 clinical trial.

The Children's Cancer Group 1952 (CCG-1952) clinical trial studied the substitution of oral 6-thioguanine (TG) for 6-mercaptopurine (MP) and triple intrathecal therapy (ITT) for intrathecal methotrexate (IT-MTX) in the treatment of standard-risk acute lymphoblastic leukemia. After remission induction, 2027 patients were randomized to receive MP (n = 1010) or TG (n = 1017) and IT-MTX (n = 1018) ...

متن کامل

Comparison of in vivo and in vitro effects of continuous exposure of L1210 cells to 6-thioguanine.

In this study the cytokinetic and antitumor effects of 12-h continuous treatment with 6-thioguanine (TG) were studied in L1210 cells in vivo and in vitro. Loss of clonogenicity in vitro was maximized at a drug concentration of 0.2 microM. Higher drug concentrations produced less cell kill, and the surviving fraction observed after exposure to 25 microM TG was 1 log higher than at 0.2 microM (2%...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 24 7  شماره 

صفحات  -

تاریخ انتشار 1997