Feasibility of simultaneous PET-MR perfusion using a novel cardiac perfusion phantom

نویسندگان

  • Jim O’Doherty
  • Eva Sammut
  • Paul Schleyer
  • James Stirling
  • Muhummad Sohaib Nazir
  • Paul K. Marsden
  • Amedeo Chiribiri
چکیده

Background: PET-MR scanners are beginning to be employed for quantitative myocardial perfusion imaging. In order to examine simultaneous perfusion calculations, this work describes a feasibility study of simultaneous PET-MR of gadolinium-based contrast agent (GBCA) and PET radiotracer in a novel cardiac perfusion phantom. Results: [F]F and GBCA were injected simultaneously into a cardiac phantom using a range of ground-truth myocardial perfusion rates of 1 to 5 ml/g/min. PET quantification of K1 (ml/g/min) was performed using a single tissue compartment model. MR perfusion was calculated using a model-independent signal deconvolution technique. PET and MR signal traces from the phantom aorta and myocardial sections show true simultaneous PET and MR arterial input functions (AIF) and myocardial uptake respectively at each perfusion rate. Calculation of perfusion parameters showed both K1 and h(t = 0) (PET and MR perfusion parameters respectively) to be linearly related with the ground truth perfusion rate (PT), and also linearly related to each other (R = 0.99). The highest difference in perfusion values between K1 and PT was 16% at 1 ml/g/min, and the mean difference for all other perfusion rates was <3%.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of high count rates on cardiac perfusion quantification in a simultaneous PET-MR system using a cardiac perfusion phantom

BACKGROUND PET-MRI is under investigation as a new strategy for quantitative myocardial perfusion imaging. Consideration is required as to the maximum scanner count rate in order to limit dead-time losses resulting from administered activity in the scanner field of view during the first pass of the radiotracer. RESULTS We performed a decaying-source experiment to investigate the high count-ra...

متن کامل

Perfusion Phantom: An Efficient and Reproducible Method to Simulate Myocardial First-Pass Perfusion Measurements with Cardiovascular Magnetic Resonance

The aim of this article is to describe a novel hardware perfusion phantom that simulates myocardial first-pass perfusion allowing comparisons between different MR techniques and validation of the results against a true gold standard. MR perfusion images were acquired at different myocardial perfusion rates and variable doses of gadolinium and cardiac output. The system proved to be sensitive to...

متن کامل

Simultaneous assessment of Perfusion with [O]water PET and arterial spin labeling MR using a hybrid PET/MR device

The combination of Positron Emission Tomography (PET) and Magnetic Resonance (MR) is a promising tool in biomedical research and clinical diagnostic imaging. In this study we performed to our knowledge the first simultaneous PET and MR perfusion measurements using [O]water, as a PET perfusion marker, and arterial spin labeling (ASL), for MR perfusion measurements, in small animals. Due to the i...

متن کامل

Compensation of Cross-Contamination in Simultaneous 201Tl/99mTc Myocardial Perfusion SPECT Imaging

Introduction: It is a common protocol to use 201Tl for the rest and 99mTc for the stress cardiac SPECT imaging. Theoretically, both types of imaging may be performed simultaneously using different energy windows for each radionuclide. However, a potential limitation is the cross-contamination of scattered photons from 99mTc and collimator X-rays into the 201Tl energy window. We used a middle en...

متن کامل

A direct comparison of the sensitivity of CT and MR cardiac perfusion using a myocardial perfusion phantom

BACKGROUND Direct comparison of CT and magnetic resonance (MR) perfusion techniques has been limited and in vivo assessment is affected by physiological variability, timing of image acquisition, and parameter selection. OBJECTIVE We precisely compared high-resolution k-t SENSE MR cardiac perfusion at 3 T with single-phase CT perfusion (CTP) under identical imaging conditions. METHODS We use...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017