This paper reviews the literature comparing the results obtained in applying regimes involving motion with those involving rest following injury or surgery. The deleterious effects of immobilisation are compared to those obtained under conditions of passive motion and intermittent passive motion. It is concluded that continuous passive motion (CPM) represents an improvement on intermittent motion. Models of CPM machines are described and some results presented. It is proposed that "intelligent" CPM would represent a further improvement in technique and a prototype machine for this purpose and some preliminary results are described. Motion is better than no motion In 1982 Bob Salter from Toronto delivered his presidential address to the Canadian Orthopaedic Association entitled, "Motion versus rest—why immobilise joints?". He observed that from the very beginnings of Western medicine there have been two schools of thought about the best way of treating injured limbs, namely the "resters" and the "movers". In the fourth century BC Hippocrates taught that in illness "it is especially needful for the body to be at rest and to lie up" while Aristotle, in the same century wrote, "the principle is that movement is life". From this time, throughout the subsequent development of orthopaedic surgery in the western world, the "resters" have maintained their popularity. It was Hugh Owen Thomas, whose dictum that rest should be "complete, prolonged, uninterrupted and enforced", who influenced generations of orthopaedic surgeons all over the world. This opinion remained unchallenged until the beginning of the twentieth century when Champonniere wrote "every movement, which is not injurious by reason of its amplitude, favours repair". He believed that "massage and motion help to relieve pain rather

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanical Simulation of the Extension and Flexion of the Elbow Joint in Rehabilitation

Objective: The goal of the present study was to improve the extension and flexion of the elbow joint for rehabilitation purposes, in terms of energy dissipation and of injuries caused by stress imposed on connective tissue by exercise equipments during force transfer , by investigation of viscoelastic property variations during change in speed of motion. Materials & Methods: A sample of five...

متن کامل

An Embedded Control Platform of a Continuous Passive Motion Machine for Injured Fingers

Human-hand is an organ easy to be injured. Hand-trauma has a high proportion in traumatic cases. About 40 percent of the cases in the emergency treatment of surgery and orthopaedics are hand trauma. Because of the subtle anatomic structure of hands and little muscles all over them, the rehabilitation of the injured hands is a tough task. Normally, the rehabilitation session is long and the reco...

متن کامل

Continuous passive motion device for hand rehabilitation.

Prototypes have been designed and manufactured for a lightweight portable device which continually moves all the joints of the hand passively through a range of motion. Inflatable bag modules in the palm of the hand are ganged together to create the required range of motion. A battery-operated air pump cycles compressed air to the modules. Initial clinical experience with patients who have flex...

متن کامل

Elbow Passive Motion Rehabilitation Utilizing a Continuous Passive Motion Device following Surgical Release, Manipulation Under Anesthesia, or Post Stable Fracture: A Review

Background Post-operative rehabilitation of the elbow following a stable fracture, surgical release or manipulation under anesthesia consists of a period of passive motion (PM) to prevent adhesions, the detrimental effects of immobilization, reduce pain, reduce inflammation and increase range of motion to a functional level. Continuous passive motion (CPM) devices have been used routinely as a ...

متن کامل

A Real-time Motion Tracking Wireless System for Upper Limb Exosuit Based on Inertial Measurement Units and Flex Sensors (TECHNICAL NOTE)

This paper puts forward a real-time angular tracking (motion capture) system for a low cost upper limb exosuit based on sensor fusion; which is integrated by an elastic sleeve-mitten, two inertial measurement units (IMU), two flex sensors and a wireless communication system. The device can accurately detect the angular position of the shoulder (flexion-extension, abduction-adduction and interna...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008