Uncertainty in patient set-up margin analysis in radiation therapy
نویسندگان
چکیده
We investigated the uncertainty in patient set-up margin analysis with a small dataset consisting of a limited number of clinical cases over a short time period, and propose a method for determining the optimum set-up margin. Patient set-up errors from 555 registration images of 15 patients with prostate cancer were tested for normality using a quantile-quantile (Q-Q) plot and a Kolmogorov-Smirnov test with the hypothesis that the data were not normally distributed. The ranges of set-up errors include the set-up errors within the 95% interval of the entire patient data histogram, and their equivalent normal distributions were compared. The patient set-up error was not normally distributed. When the patient set-up error distribution was assumed to have a normal distribution, an underestimate of the actual set-up error occurred in some patients but an overestimate occurred in others. When using a limited dataset for patient set-up errors, which consists of only a small number of the cases over a short period of time in a clinical practice, the 2.5% and 97.5% intervals of the actual patient data histogram from the percentile method should be used for estimating the set-up margin. Since set-up error data is usually not normally distributed, these intervals should provide a more accurate estimate of set-up margin. In this way, the uncertainty in patient set-up margin analysis in radiation therapy can be reduced.
منابع مشابه
Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties
Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...
متن کاملUtilization of Electronic Portal Imaging Device (EPID) For Setup Verification and Determination of Setup Margin in Head and Neck Radiation Therapy
Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in head and neck cancer patients. Material and Methods: A total of 15 patients who had daily p...
متن کاملA Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom
Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D) XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion...
متن کاملRespiratory motion effect on tumor and normal tissue doses in patients with lung cancer, treated with Intensity Modulation Radiation Therapy and Three Dimensional Conformal Radiation Therapy.
Introduction: The aim of this study is to investigate the effect of respiratory motion during radiation therapy in patient with lung cancer and comparison of dosimetric parameters between Intensity modulation radiation therapy and three-dimensional conformal radiotherapy in lung cancer. Materials and Methods: Two CT scan was performred for each pati...
متن کاملUncertainty Analysis in MRI-based Polymer Gel Dosimetry
Background: Polymer gel dosimeters combined with magnetic resonance imaging (MRI) can be used for dose verification of advanced radiation therapy techniques. However, the uncertainty of dose map measured by gel dosimeter should be known. The purpose of this study is to investigate the uncertainty related to calibration curve and MRI protocol for MAGIC (Methacrylic and Ascorbic acid in Gelatin I...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 53 شماره
صفحات -
تاریخ انتشار 2012