Intracardiac voltage gradients during transthoracic defibrillation: implications for postshock myocardial injury.

نویسندگان

  • James T Niemann
  • Robert G Walker
  • John P Rosborough
چکیده

UNLABELLED In-vitro studies indicate that the electric-field intensity, or voltage gradient (VG), generated by a defibrillation shock is a determinant of defibrillation success as well as potential shock-induced cardiac injury. It is not clear how common descriptors of shock dose, e.g., joules (J), relate to VGs. OBJECTIVES To assess the relationships between shock energy descriptors and VG. METHODS One monophasic and three biphasic waveforms were compared using transthoracic shocks and standard electrodes in five swine. VG measurements via intracavitary multielectrode-tipped catheters were compared with delivered energy and peak current. Shock variables were recorded at native transthoracic impedance and an adjusted impedance approximating that of typical humans. RESULTS For shocks at the same energy setting, peak current and VGs varied widely among the four defibrillators. At simulated human impedance (75 Omega), shocks at each device's maximum energy setting produced similar VGs among the three biphasic defibrillators, despite different delivered energies. For both native impedance (35 Omega) and at 75 Omega, VG correlated with peak current (r = 0.81 and 0.77, respectively) but not energy setting (r = 0.61, 0.52) or delivered energy (r = 0.58, 0.56). At the maximum energy setting of each device, maximum recorded VGs for both monophasic (33 V/cm) and biphasic (24 V/cm) defibrillators were less than those reported to cause myocardial injury (>60 to 80 V/cm). CONCLUSIONS Energy descriptors correlate poorly to actual shock intensities. When compared with reported VG thresholds of myocardial injury, this study suggests that risk of injury from critically strong VGs is low for all of these defibrillators and equivalent among tested biphasic waveforms.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

BRIEF REVIEW Determinants of successful defibrillation

Ventricular defibrillation by electric counter shock is the definitive treatment for cardiac arrest due to ventricular fibrillation (VF). Ventricular defibrillation is the fundamental cornerstone to a successful outcome. As most deaths from VF occur out of hospital, often in patients without pre-existent recognised cardiac disease, the major public health issue remains the widespread applicatio...

متن کامل

Improved safety factor for triphasic defibrillator waveforms.

Newly developed biphasic waveforms improve defibrillation efficacy both by reduction of defibrillation threshold and by amelioration of shock-induced dysfunction depending on the relative shape of the first and second pulses. Each of these independent effects improves the waveform's safety factor, the ratio between the shock intensity that produces a specific degree of postshock dysfunction and...

متن کامل

Emergency intracardiac defibrillation for refractory ventricular fibrillation during routine electrophysiologic study.

Ventricular fibrillation refractory to cardiopulmonary resuscitation including multiple transthoracic defibrillations occurred in four patients during 1,215 consecutive ventricular tachycardia induction studies. A technique of emergency intracardiac defibrillation for management of refractory ventricular fibrillation is described. In four patients, stable monomorphic ventricular tachycardia (32...

متن کامل

Internal cardioversion of atrial fibrillation in sheep.

BACKGROUND The cardioversion efficacy of multiple defibrillation waveforms and electrode systems was compared in a sheep model of atrial fibrillation. METHODS AND RESULTS Sustained atrial fibrillation could be induced with rapid atrial pacing in 23 (55%) of the animals. This study was performed in four parts. Six sheep with sustained atrial fibrillation were used for data analysis for each pa...

متن کامل

Impact of myocardial ischemia and reperfusion on ventricular defibrillation patterns, energy requirements, and detection of recovery.

BACKGROUND Shocks that have defibrillated spontaneous ventricular fibrillation (VF) during acute ischemia or reperfusion may seem to have failed if VF recurs before the ECG amplifier recovers after shock. This could explain why the defibrillation threshold (DFT) for spontaneous VF appears markedly higher than for electrically induced VF. METHODS AND RESULTS The DFT for electrically induced VF...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Academic emergency medicine : official journal of the Society for Academic Emergency Medicine

دوره 12 2  شماره 

صفحات  -

تاریخ انتشار 2005