Calibration of wrist-mounted robotic sensors by solving homogeneous transform equations of the form AX=XB

نویسندگان

  • Yiu Cheung Shiu
  • Shaheen Ahmad
چکیده

Abstruct-In order to use a wrist-mounted sensor (such as a camera) for a robot task, the position and orientation of the sensor with respect to the robot wrist frame must be known. We can find the sensor mounting position by moving the robot and observing the resulting motion of the sensor. This yields a homogeneous transform equation of the form A X = XB, where A is the change in the robot wrist position, B is the resulting sensor displacement, and X is the sensor position relative to the robot wrist. The solution to an equation of this form has one degree of rotational freedom and one degree of translation freedom if the angle of rotation of A is neither 0 nor ?r radians. To solve for X uniquely, it is necessary to make two arm movements and form a system of two equations of the form: A , X = XB, and A& = X&. A closed-form solution to this system of equations is developed and the necessary conditions for uniqueness are stated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensor calibration with unknown correspondence: Solving AX=XB using Euclidean-group invariants

The AX = XB sensor calibration problem must often be solved in image guided therapy systems, such as those used in robotic surgical procedures. In this problem, A, X , and B are homogeneous transformations with A and B acquired from sensor measurements and X being the unknown. It has been known for decades that this problem is solvable for X when a set of exactly measured A’s and B’s, in a prio...

متن کامل

Hand - Eye Calibration 1

{ Whenever a sensor is mounted on a robot hand it is important to know the relationship between the sensor and the hand. The problem of determining this relationship is referred to as the hand-eye calibration problem. Hand-eye calibration is important in at least two types of tasks: (i) map sensor centered measurements into the robot workspace frame and (ii) allow the robot to precisely move th...

متن کامل

Hand-Eye Calibration

Whenever a sensor is mounted on a robot hand it is important to know the relation ship between the sensor and the hand The problem of determining this relationship is referred to as the hand eye calibration problem Hand eye calibration is important in at least two types of tasks i map sensor centered measurements into the robot workspace frame and ii allow the robot to precisely move the sensor...

متن کامل

Gauss-Sidel and Successive Over Relaxation Iterative Methods for Solving System of Fuzzy Sylvester Equations

In this paper, we present Gauss-Sidel and successive over relaxation (SOR) iterative methods for finding the approximate solution system of fuzzy Sylvester equations (SFSE), AX + XB = C, where A and B are two m*m crisp matrices, C is an m*m fuzzy matrix and X is an m*m unknown matrix. Finally, the proposed iterative methods are illustrated by solving one example.

متن کامل

On The Simulation of Partial Differential Equations Using the Hybrid of Fourier Transform and Homotopy Perturbation Method

In the present work, a hybrid of Fourier transform and homotopy perturbation method is developed for solving the non-homogeneous partial differential equations with variable coefficients. The Fourier transform is employed with combination of homotopy perturbation method (HPM), the so called Fourier transform homotopy perturbation method (FTHPM) to solve the partial differential equations. The c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • IEEE Trans. Robotics and Automation

دوره 5  شماره 

صفحات  -

تاریخ انتشار 1989