ExtaviJect® 30G device for subcutaneous self-injection of interferon beta-1b for multiple sclerosis: a prospective European study

نویسندگان

  • Gabriel Boeru
  • Ivan Milanov
  • Francesca De Robertis
  • Wojciech Kozubski
  • Michael Lang
  • Sònia Rojas-Farreras
  • Mark Tomlinson
چکیده

BACKGROUND The ExtaviJect® 30G autoinjector was developed to facilitate parenteral self-administration of interferon beta-1b (Extavia®), a first-line disease-modifying therapy in patients with multiple sclerosis. Our aim was to assess patient compliance with treatment when using the autoinjector, patients' and nurses' experiences of using the device, its tolerability, and patient satisfaction. METHODS This was a 12-week, real-world, prospective, observational, noninterventional study conducted in nine European countries. Questionnaires were used to measure patient compliance and to assess patients' and nurses' experiences. All adverse events were recorded by severity, including injection site reactions or pain. Patient satisfaction and health-related quality of life were assessed using the Treatment Satisfaction Questionnaire for Medication-9 (TSQM-9) and EuroQol-5 Dimension (EQ-5D) instruments, respectively. RESULTS Of 582 patients enrolled, 568 (98%) received at least one injection and attended the first follow-up visit at 6 weeks, and 542 (93%) attended the second follow-up visit at 12 weeks. For the whole study, 548 of 568 (97%) patients were compliant with treatment. Among the various questions assessing whether the device was easy and quick to use accurately, without fear of the needle, 56%-98% of patients and 59%-98% of nurses were in agreement. There were nine serious adverse events (four disease-related) reported among the 227 (39%) patients reporting adverse events. Scores increased in the TSQM-9 convenience domain between weeks 6 and 12 (P=0.0009), and in the EQ-5D visual analog scale between baseline and week 12 (P<0.0001), indicating improvement in health-related quality of life. CONCLUSION ExtaviJect 30G was convenient to use and was associated with high levels of compliance.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Autoinjectors for administration of interferon beta-1b in multiple sclerosis: patient preferences and the ExtaviPro™ 30G and Betacomfort® devices

BACKGROUND The ExtaviPro™ 30G autoinjector has been developed for self-administration of interferon beta-1b (Extavia®), which is used as a first-line, parenteral, disease-modifying therapy in multiple sclerosis (MS). The aim of this survey was to investigate patients' perceptions of the importance of different general attributes of autoinjectors, and patient preferences when comparing the Extav...

متن کامل

Patient satisfaction with ExtaviPro™ 30G, a new auto-injector for administering interferon β-1b in multiple sclerosis: results from a real-world, observational EXCHANGE study

BACKGROUND Patients with multiple sclerosis (MS) receiving long-term, subcutaneous interferon β-1b (IFN β-1b; Extavia®) often experience injection-site reactions and injection-site pain, which together with other side-effects (such as flu-like symptoms) result in suboptimal treatment compliance/adherence. The EXCHANGE study evaluated patient satisfaction with IFN β-1b treatment, administered us...

متن کامل

Understanding and meeting injection device needs in multiple sclerosis: a survey of patient attitudes and practices

BACKGROUND All established disease-modifying drugs for multiple sclerosis require parenteral administration, which can cause difficulties for some patients, sometimes leading to suboptimal adherence. A new electronic autoinjection device has been designed to address these issues. METHODS Patients with relapsing multiple sclerosis currently receiving subcutaneous or intramuscular interferon be...

متن کامل

Porokeratosis of Mibelli: a new indication for photodynamic therapy?

1. Gaines AR, Varricchio F. Interferon beta-1b injection site reactions and necroses. Mult Scler. 1998;4:70. 2. Aguilar G, Serrano C, Carmona M, Linares J, Serrano S. Necrosis cutánea por interferón alfa en paciente con melanoma. Actas Dermosifiliogr. 2006;97:539--42. 3. Beiske AG, Myhr KM. Lipoatrophy: a non-reversible complication of subcutaneous interferon-beta 1a treatment of multiple scler...

متن کامل

تجزیه و تحلیل فیلوژنتیکی و آنالیز In Silico پروتئین اینترفرون بتا 1 بی

Background and purpose: Interferon beta-1b recombinant protein is used for reducing the relapse rate and treatment in patients with Multiple sclerosis (MS). In this study, phylogenetic and in silico analysis of interferon beta-1b were conducted by servers and bioinformatics tools to predict its structural potential. Materials and methods: Physiological and physico-chemical characteristics of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2013