Bayesian Motion Estimation for Temporally Recursive Noise Reduction in X-ray Fluoroscopy

نویسندگان

  • D. KUNZ
  • T. Aach
  • D. Kunz
چکیده

s This paper develops a Bayesian motion estimation algorithm for motioncompensated temporally recursive filtering of moving low-dose X-ray images (X-ray fluoroscopy). These images often exhibit a very low signalto-noise ratio. The described motion estimation algorithm is made robust against noise by spatial and temporal regularization. A priori expectations about the spatial and temporal smoothness of the motion vector field are expressed by a generalized Gauss-Markov random field. The advantage of using a generalized Gauss-Markov random field is that, apart from smoothness, it also captures motion edges without requiring an edge detection threshold. The costs of edges are controlled by a single parameter, by means of which the influence of the regularization can be tuned from a median-filter-like behaviour to a linear-filter-like one.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Robust Motion Vector Relaxation for X - RayFluoroscopy Using Generalized Gauss - MarkovRandom

We describe a Bayesian motion estimation algorithm which is part of a temporally recursive noise reduction lter for X-ray uo-roscopy images. Our algorithm draws its robustness against high quantum noise levels from a statistical regularization, where a priori expectations about the spatial and temporal smoothness of motion vector elds are modelled by generalized Gauss-Markov random elds. We sho...

متن کامل

Noise Reduction and Image Enhancement Algorithms for Low-Dose X-Ray Fluoroscopy

After describing our quantum noise model, we rst develop a new motion-adaptive temporal lter based on a recursive structure. Compared to other motion-adaptive lters, our lter is much less prone to generate artefacts known as noise tails. We then describe spatial ltering techniques derived from the concept of spectral amplitude estimation. These lters work in the spectral domain, and can conveni...

متن کامل

Enhancement of Low-Dosage Cine-angiographic Image Sequences using a Modified Expectation Maximization algorithm

Clinical x-ray image sequences acquired through fluoroscopy systems may be corrupted by quantum mottle — a Poisson-distributed, signal-dependent noise that arises with a controlled x-ray dosage reduction in an attempt to lower the exposure to the patient and the medical staff. In this paper, an approach to temporally filter this sequence is presented. It relies on a joint estimation of the sign...

متن کامل

Surrogate-Driven Estimation of Respiratory Motion and Layers in X-Ray Fluoroscopy

Dense motion estimation in X-ray fluoroscopy is challenging due to low soft-tissue contrast and the transparent projection of 3-D information to 2-D. Motion layers have been introduced as an intermediate representation, but so far failed to generate plausible motions because their estimation is ill-posed. To attain plausible motions, we include prior information for each motion layer in the for...

متن کامل

Evaluation of the Quality Control Program for Diagnostic Radiography and Fluoroscopy Devices in Syria during 2005-2013

Introduction: Extensive use of diagnostic radiology is the largest contributor to total population radiation doses. Thus, appropriate equipment and safe practice are necessary for good-quality images with optimal doses. This study aimed to perform quality control (QC) audit for radiography and fluoroscopy devices owned by private sector in Syria (2005-2013) to verify compliance of performance o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014