Use of B-mode ultrasonography for measuring femoral muscle thickness in dogs
نویسندگان
چکیده
Assessment of muscle mass is important for evaluating muscle function and rehabilitation outcomes. Ultrasound has recently been successfully used to estimate muscle mass in humans by measuring muscle thickness. This study attempted to standardize procedures for measuring femoral muscle thickness ultrasonographically, as well as quantify the reliability and validity of ultrasound evaluations of muscle thickness compared to measurements made by magnetic resonance imaging (MRI) in dogs. We evaluated the quadriceps femoris (QF), biceps femoris (BF), semitendinosus (ST) and semimembranosus (SM) muscles of 10 clinically healthy Beagle dogs. Scans were taken in 5 different sections divided equally between the greater trochanter and proximal patella. MRI was performed, followed by T1-weighted and contrast-enhanced T1-weighted imaging. Muscle cross-sectional area (CSA) was measured with MRI, and muscle thickness was measured with MRI and ultrasonography. The thickness of the QF, BF and ST muscles as measured by ultrasound at slices 1-3 (from the proximal end to the middle of the femur), 2-4 (middle of the femur) and 2 (more proximal than the middle of the femur), respectively, was correlated with muscle thickness and CSA as measured by MRI. These sites showed a flat interface between muscle and transducer and were situated over belly muscle. No correlation between measurement types was seen in SM muscle. We must confirm this assessment method for various breeds, sizes, ages and muscle pathologies in dogs, thereby confirming that muscle thickness as measured ultrasonographically can reflect muscle function.
منابع مشابه
Normal Color and Pulsed-Waved Doppler Ultrasonography of Femoral and Axillary Arteries in Dogs
Objective- Obtaining the normal images ofcolor doppler and estimation ofblood flow velocity parametersof femoral and axillary arteries in dog.Design- Descriptive studyAnimals- 7 healthy adult mixed-breed dogs, weighing 14.3 ± 2.8 kg (mean ± SD).Proceudure- Left and right femoral and axillary arteries of hind and forelimbs were evaluated. Colorand spectral doppler images ofthe each artery were o...
متن کاملIntra-rater reliability of sonographic measurement of the upper trapezius, supraspinatus and deltoid muscles in women with frozen shoulder and healthy women
Background: Some studies show that frozen shoulder is due to the pathologic changes in the muscles around the shoulder. Measurement of the ultrasonic thickness of a muscle is a method for measuring the muscle changes. There is no study about the reliability of measurement of the muscle’s ultrasonic thickness around the shoulder in patients with frozen shoulder. The present study aims to invest...
متن کاملRelationship between sprint performance of front-crawl swimming and muscle fascicle length in young swimmers
The purpose of this study was to investigate the relationship between sprint performance of front-crawl swimming and muscle fascicle length in 23 male young swimmers. The sample was divided into two groups by 25-m sprint front-crawl swimming performance: 14.6-15.7 s (S1, n=11) and 15.8-17 s (S2, n=12). Muscle thickness and pennation angle and fascicle length of the Biceps Brachii (only muscle t...
متن کاملArterial wall thickness measurements by B mode ultrasonography in patients with Takayasu's arteritis.
OBJECTIVE To assess the feasibility and potential diagnostic usefulness of arterial ultrasonography in Takayasu's arteritis. METHODS The total wall, intimal + medial, and adventitial thickness of the common carotid, subclavian and common femoral arteries, and of the abdominal aorta, were examined by B mode ultrasonography in 16 patients with Takayasu's arteritis and 16 healthy control subject...
متن کاملB-scan ultrasonography of ocular abnormalities: a review of 182 dogs
Ultrasonography is the only practical method for obtaining images of the posterior segment of the eye when the light-conducting media are opaque. In this study, 182 dogs with ocular abnormalities presented to the Department of Veterinary Surgery and Radiology from December 2008-August 2010 were included. All the animals were subjected to detailed ophthalmic examination and B-scan ultrasonograph...