Relative potency of commercial calibrators for fructosamine, and their effect on measurements of fructosamine in serum.
نویسندگان
چکیده
The protein-based secondary standardsfor serum fructosamine in a commercial test kit (Roche Diagnostics) have recently been modified by the manufacturer. Under certain assay conditions, the new calibrator gave significantly greater serum fructosamine values than those obtained with the originally supplied calibrator. However, for 20-4, samples and absorbance measurements at 10 and 15 mm, hereafter called “calibrator conditions,” assay values were unaffected. Table 1 summarizes our results for comparing the activity in the new protein standard (lot K3034) with that in the old (lot C0342). The relative activity of the calibrators in reducing nitroblue tetrazolium was calculated from changes in absorbance measurements, ,..,,Jmin, over 1-15 mm with 10and 20-4, samples. We performed the evaluations with sera from non-selected patients and carried out all measurements with a Cobas Bio centrifugal analyzer and reagents supplied with the kit. The relative decrease in the activity of the new calibrator as the pre-incubation time of the assay was shortened caused an apparent shift towards higher values for serum fructosamine measured with use of the new calibratori.e., serum fructosamine concentration = k X Meample/AAcalibrator, where k is the assigned calibrator concentration. Sample volumes less than 20 /LL in the assays with the new calibrator caused a shift towards values for serum fructosanune higher than those obtained with the old calibrator. The activity of the old calibrator, like that of serum, showed a nonlinear dilution effect, and decreased less than in proportion to the dilution (2). In contrast, the new calibrator showed a linear dilution effect; i.e., at the same nomiTable 1. Relative Activity of New and Old Fructosamine Assay Calibrators Assay timIng, mln
منابع مشابه
Diagnostic Value of Fructosamine and Glycosylated Hemoglobin in Estimating Blood Glucose Level in Diabetic Patients with Thalassemia Major
Abstract Background and Objective: Diabetes mellitus is one of complications that thalassemia major patients face with. Hence, blood glucose monitoring is of vital importance to these patients. Because of high level of fetal hemoglobin in these patients, the measurement of hemoglobin A1c is not reliable and should be displaced by fructosamine test. Material and Methods: The current descr...
متن کاملEffect of Curcumin Supplementation on Fructosamine Level, Blood Lipids, Lipid Peroxidation and Hepatic Enzymes in Type 2 Diabetics
Objective: DM is a major medical problem in developing countries such as Iran. Blood sugar and lipids levels increase in diabetics exacerbates the onset of diabetes mellitus (DM) late complications. Researchers have focused on herbal medicines improve sugar and lipid levels against side decreasing effects and possible inefficacy of chemical drugs. This study has assessed the effect of curcumin ...
متن کاملSerum Glucose and Fructosamine in Relation to Risk of Cancer
BACKGROUND Impaired glucose metabolism has been linked with increased cancer risk, but the association between serum glucose and cancer risk remains unclear. We used repeated measurements of glucose and fructosamine to get more insight into the association between the glucose metabolism and risk of cancer. METHODS We selected 11,998 persons (>20 years old) with four prospectively collected se...
متن کاملInfluence of timing in the fructosamine assay.
The fructosamine assay, based on the measurement of the reducing activity in serum at alkaline pH, provides an index of protein glycation. The reducing activity is expressed in equivalents of 1-deoxy-1-morpholinofructose (DMF) by direct comparison with the activity either of this synthetic compound or with a secondary protein standard calibrated against DMF. This study reports the influence of ...
متن کاملLaboratory assessment of a commercial kit for measuring fructosamine in serum.
We have evaluated the laboratory performance and clinical usefulness of the Roche fructosamine kit. As used with an Abbott ABA 100 bichromatic analyzer, the kit response varied linearly with fructosamine concentration to 5.0 mmol/L (deoxymorpholinofructose equivalents). Interbatch precision was 4.1% and 3.6% for respective fructosamine concentrations of 3.2 and 5.0 mmol/L; intrabatch precision ...