Failure of asnis iii 5.0 mm cannulated screw: a case report

نویسندگان

  • A Chen
  • C Willis-Owen
  • K Akhtar
  • S Kamineni
چکیده

We describe a case of an ASNIS III 5.0 mm partially threaded cannulated screw unthreading itself as it was being inserted during fracture fixation of a humerus. The majority of complications associated with cannulated screws involve breaking of the screw, as opposed to unthreading. We believe that the self tapping design of the screw, in combination with the cannulated design, creates a potential area of weakness when used on hard bone.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Performance of Cannulated Compression Screws: Fixos Ø4.0, 5.0 & 7.0 mm compared to Asnis III

Introduction: The biomechanical screw performance plays a crucial role on the early interfragmentary stability and, in turn, on the fracture healing outcome. Therefore, this study compares the biomechanical performance of the cannulated headless compression screws Fixos Ø4.0, 5.0 & 7.0 mm to the standard cannulated compression screws Asnis III. Materials & Method: Interfragmentary compression f...

متن کامل

Unusual mode of mechanical failure of an AO cannulated self drilling screw. A case report.

Cannulated AO screws are commonly used for fracture fixation. Mechanical failure of screws has been well reported but this was mainly breakage of the screw head during removal. We report an unusual mode of failure of an AO self drilling cannulated screw which we have not previously experienced, where the screw threads were found to be unravelled during insertion. We also suggest the way to reco...

متن کامل

Clinical and radiological outcomes of arthroscopically assisted cannulated screw fixation for tibial eminence fracture in children and adolescents

BACKGROUND The purpose of this study was to determine the efficacy and complications of arthroscopically assisted reduction and fixation with cannulated screws for tibial eminence fracture in skeletally immature patients. METHODS This was a retrospective case series study. Forty-eight patients who were skeletally immature at the time of tibial eminence fracture were treated in a tertiary chil...

متن کامل

Bilateral Simultaneous Femoral Neck and Shafts Fractures – A Case Report

  Simultaneous fractures of the femoral neck and shaft are not common injuries, though they cannot be considered rare. Herein, we report our experience with a patient with bilateral occurance of this injury. Up to the best of our knowkedge this is the first case reported in literature in which correct diagnosis was made initially. Both femurs were fixed using broad 4.5 mm dynamic compression pl...

متن کامل

Solid screw insertion for tension band plates: a surgical technique tip

PURPOSE Growth modulation with tension band plates (TBPs) and cannulated screws is the current mainstay of treatment for pediatric lower extremity angular deformities. Solid screws have been used as an alternative to cannulated screws to decrease the risk of screw failure, particularly in obese children. The downside of solid screws is the decrease in precision of placement. This study describe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2010