Ultrasound detection of guidewire position during central venous catheterization.

نویسندگان

  • Michael B Stone
  • Arun Nagdev
  • Michael C Murphy
  • Craig A Sisson
چکیده

INTRODUCTION Ultrasound guidance decreases complications of central venous catheter (CVC) placement, but risks of arterial puncture and inadvertent arterial catheter placement exist. Ultrasound-assisted detection of guidewire position in the internal jugular vein could predict correct catheter position before dilation and catheter placement. METHODS Ultrasound examinations were performed in an attempt to identify the guidewire before dilation and catheter insertion in 20 adult patients requiring CVC placement. Central venous pressures were measured after completion of the procedure. RESULTS Guidewires were visible within the lumen of the internal jugular vein in all subjects. Central venous pressures confirmed venous placement of catheters. Ultrasound visualization of the guidewire predicted venous CVC placement with 100% sensitivity (95% confidence interval 80-100%) and 100% specificity (95% confidence interval 80%-100%). CONCLUSIONS Ultrasound reliably detects the guidewire during CVC placement and visualization of the wire before dilation and catheter insertion may provide an additional measure of safety during ultrasound-guided CVC placement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasound Guidance for Central Venous Catheterization: A Step Further to Prevent Malposition of Central Venous Catheter before Radiographic Confirmation

Ultrasound (USG) guidance has long been used for guiding central venous catheterization. USG provides direct visualization of needle puncture through the skin into the vein. Most of the time USG guidance is just limited to puncturing of the vein and seeing guidewire entering the vein while malpositioning of catheter occurs after that which is seen later on while checking chest radiograph. Repos...

متن کامل

Fracture of J-tipped guidewire during central venous catheterization and its successful removal under fluoroscopic guidance -A case report-

Central venous catheterization by Seldinger's technique uses a guidewire which may cause complications such as kinking, knotting and fracture. Fractured guidewire may lead to severe outcomes such as embolization, and removal of it may also cause problems such as vessel damage. We experienced a case of right internal jugular venous catheterization complicated by guidewire fracture entrapped in t...

متن کامل

A complication of subclavian venous catheterization: extravascular kinking, knotting, and entrapment of the guidewire -A case report-

Various complications of central venous catheterization have been reported, some of which are well-known, while others are described as a sporadic events. We experienced a case of left subclavian venous catheterization complicated by extravascular knotting, kinking, and entrapment of the guidewire and the guidewire was removed surgically. Although minimal resistance was encountered during guide...

متن کامل

Successful removal of kinked J-guide wire under fluoroscopic guidance during central venous catheterization -A case report-

Guidewire-associated complications that occur during the process of central venous catheterization include its kinking, looping, knotting and breakage. The removal of a looped or knotted guidewire is problematic because it can cause vessel damage, major hemorrhage, or embolization of a fractured guidewire. We report a case of guidewire kinking and its successful removal under fluoroscopic guida...

متن کامل

Ultrasound-guided infraclavicular axillary vein cannulation for central venous access.

BACKGROUND Infraclavicular axillary vein cannulation is not commonly used for central venous access because identifying the surface landmarks is difficult. Ultrasound guided axillary vein puncture has not been well described. We assessed ultrasound imaging to guide catheterization of the infraclavicular axillary vein. METHODS In 200 consecutive patients we attempted to catheterize the axillar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of emergency medicine

دوره 28 1  شماره 

صفحات  -

تاریخ انتشار 2010