Use of DWI in identification of small solid pancreatic focalities (≤ 2 cm).

نویسندگان

  • Francesco Negri
  • Nicola Emanuele Bono
  • Sandro Barbalace
  • Vincenzo Trunfio
  • Silvia Lana
  • Chiara Ganazzoli
  • Emanuela Angela Marcantoni
  • Marilina Totaro
  • Manuela Vallara
  • Raffaele Parziale
  • Daniele Borgia
چکیده

Incidental finding of pancreatic focalities has increased thanks to a larger use of radiological examinations (Ultrasound, CT). The differential diagnosis between focal inflammatory and heteroplastic disease is frequently complicated by the wide spectrum of lesions and by the aspecificity of clinical and medical history, as well as of imaging findings. MRI is the second level choice of examination thanks to its higher intrinsic contrast resolution and parametric capability (1); furthermore, the use of Diffusion Weighted Imaging (DWI) sequences provides additional diagnostic informations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

گزارش بیمار مبتلا به سل ایزوله‌ی پانکراس: گزارش موردی

Background: Although Tuberculosis (TB) is prevalent in developing countries, visceral TB is rare. Most cases of pancreatic tuberculosis are seen in association with disseminated TB (miliary) but isolated pancreatic infection is very rare. Especially when present in immunocompetent hosts. In clinical and radiological evaluation, pancreatic TB may present as a pancreatic abscess, acute or chronic...

متن کامل

Reduced Field-of-View Diffusion-Weighted Magnetic Resonance Imaging of the Pancreas: Comparison with Conventional Single-Shot Echo-Planar Imaging

OBJECTIVE To investigate the image quality (IQ) and apparent diffusion coefficient (ADC) of reduced field-of-view (FOV) di-ffusion-weighted imaging (DWI) of pancreas in comparison with full FOV DWI. MATERIALS AND METHODS In this retrospective study, 2 readers independently performed qualitative analysis of full FOV DWI (FOV, 38 × 38 cm; b-value, 0 and 500 s/mm(2)) and reduced FOV DWI (FOV, 28...

متن کامل

Dose Calculations for Lung Inhomogeneity in High-Energy Photon Beams and Small Beamlets: A Comparison between XiO and TiGRT Treatment Planning Systems and MCNPX Monte Carlo Code

Introduction Radiotherapy with small fields is used widely in newly developed techniques. Additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. In the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against Monte Carlo method. Materials and Methods Siemens Once or linea...

متن کامل

Diffusion- and Perfusion-Weighted Imaging in Acute Lacunar Infarction: Is There a Mismatch?

PURPOSE Characterization of lacunar infarction (LI) by use of multimodal MRI including diffusion- and perfusion-weighted imaging (DWI, PWI) is difficult because of the small lesion size. Only a few studies evaluated PWI in LI and the results are inconsistent. METHODS In 16 LI patients who underwent initial MRI within 6 hours after symptom onset and follow-up MRI within 1 week demographics, cl...

متن کامل

The management of cystic lesions of the pancreas.

The number of patients being identified as having asymptomatic small cysts of the pancreas is increasing. Most cystic neoplasms are SCAs, IPMNs, or MCNs. SCAs should be considered benign and in the absence of symptoms can be safely followed radiographically. Currently, most patients who present with mucinous cysts should undergo resection, because many of these patients have in situ or invasive...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Acta bio-medica : Atenei Parmensis

دوره 87 Suppl 3  شماره 

صفحات  -

تاریخ انتشار 2016