Snake modeling and distance transform approach to vascular centerline extraction and quantification.
نویسندگان
چکیده
A new method for fully automated centerline extraction and quantification of microvascular structures in confocal microscopy (CM) images is presented. Our method uses the idea of active contour models as well as path planning and distance transforms for the three-dimensional centerline extraction of elongated objects such as vessels. The proposed approach is especially efficient for centerline extraction of complex branching structures. The method performance is validated in several CM images of both normal and stroked rat brains as well as simulated objects. The results confirm the efficiency of the proposed method in extracting the medial curve of vessels, which is essential for the computation of quantitative parameters.
منابع مشابه
Fast center-line extraction for quantification of vessels in confocal microscopy images
In this paper we present a novel method for the 3D centerline extraction of elongated objects such as vessels. This method unites the basic ideas in distance transformbased, thinning, and path planning methods to extract thin and connected centerlines. This fast approach needs no user interaction or any prior knowledge of the object shape. Centerline extraction is the first and most important s...
متن کاملA distance-field-based approach in generating cross-sections for 2-D vessel quantification [5746-89]
For accurate determination of thickness-profile in vessel quantification, it is important to find appropriate vessel crosssections. To obtain vessel cross-sections, a centerline-based approach has been widely used, but it has several inherent problems causing improper cross-sections. First, this approach cannot define cross-sections in a unique way. Second, cross-sections are sensitive to the d...
متن کاملRobust Centerline Extraction from Tubular Structures in Medical Images
Extraction of centerlines is useful to analyzing objects in medical images, such as lung, bronchia, blood vessels, and colon. Given the noise and other imaging artifacts that are present in medical images, it is crucial to use robust algorithms that are (1) noise tolerant, (2) computationally efficient, (3) accurate and (4) preferably, do not require an accurate segmentation and can directly op...
متن کاملFlux driven medial curve extraction
In this document it is described the implementation of the flux driven automatic centerline extraction algorithm proposed by Bouix et al. in 2004. This is based on a skeletonisation algorithm initially proposed by Siddiqi et al. in 2002, using properties of an average outward flux measure to distinguish skeletal points from non-skeletal ones. This information is combined with a topology preserv...
متن کاملQuantifying the vascular profile of a tumor by 3D Euclidean distance maps
Introduction: The complexity of the vascular morphology of tumors presents a quantification problem to identify vascular changes in MRA studies that image tumor vasculature to understand the effects of treatment. A practical quantification method to analyze the vascular data will considerably benefit these studies. We propose a computationally robust approach that quantifies the vasculature bas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society
دوره 27 6 شماره
صفحات -
تاریخ انتشار 2003