Energy Resolution and Rise Time of HPGe Detectors in High Magnetic Fields

نویسندگان

  • A. Sanchez Lorente
  • A. Pantaleo
  • G. Raciti
  • K. Szymanska
چکیده

Future experiments on hypernuclear high-resolution γ-spectroscopy with high-purity germanium detectors with the FINUDA apparatus at the DAΦNE accelerator and with the PANDA apparatus at the FAIR facility require the operation of these detectors in high magnetic fields (B ≈ 1T). VEGA and Euroball cluster HPGe detectors were tested in the field provided by the ALADiN magnet at GSI. A small degradation of the energy resolution by 1–2 keV was found, and a change in the rise time of the pulses by 50–200 ns was observed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of HPGe Detectors in High Magnetic Fields

A new generation of high-resolution hypernuclear γ-spectroscopy experiments with high-purity germanium detectors (HPGe) are presently designed at the FINUDA spectrometer at DAΦNE, the Frascati φ-factory, and at PANDA , the pp hadron spectrometer at the future FAIR facility. Both, the FINUDA and PANDA spectrometers are built around the target region covering a large solid angle. To maximise the ...

متن کامل

Determination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods

High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...

متن کامل

A Comparative Study of Field Gamma-ray Spectrometry by NaI(Tl) and HPGe Detectors in the South Caspian Region

Natural radionuclides present in soil as well as certain anthropogenic radionuclides released to the environment are the major contributors to terrestrial outdoor exposures. In the assessment of human exposures from environmental radioactivity, besides the conventional method of soil and vegetation sampling combined with laboratory based analyses of environmental media, the other choice would b...

متن کامل

Performance of a Radiation Portal Freight Monitor based on Integrated Germanium Detector Modules

Portal monitors, container scanners, and mobile search systems, constructed with high resolution germanium (HPGe) detectors, are currently being installed at locations world-wide. This reflects a general desire for improved performance and a reduction in the time to make a good decision in interdiction cases. An integrated gamma-ray spectrometer, incorporating a mechanically-cooled HPGe detecto...

متن کامل

Ultraviolet detectors based on annealed zinc oxide thin films: epitaxial growth and physical characterizations

In this report, ultraviolet (UV) detectors were fabricated based on zinc oxide thin films. The epitaxial growth of zinc oxide thin films was carried out on bare glass substrate with preferred orientation to (002) plane of wurtzite structure through radio frequency sputtering technique. The structural properties indicated a dominant peak at 2θ=34.28º which was matched with JCPDS reference card N...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006