The imaging assessment and specific endograft design for the endovascular repair of ascending aortic dissection
نویسندگان
چکیده
BACKGROUND Endovascular option has been proposed for a very limited and selected number of Stanford type A aortic dissection (TAAD) patients. We have performed a computed tomography (CT)-based TAAD study to explore appropriate endograft configurations for the ascending aortic pathology. METHODS TAAD patients treated with optimal CT scans were retrospectively reviewed, and their entry tears (ETs) were identified using three-dimensional and multiplanar reconstructions in an EndoSize workstation. After generating a centerline of flow, measurements, including numerous morphologic characteristics of anatomy, were evaluated and a selected subset of patients were determined to be suitable for endovascular treatments. Proximal diameter and distal diameter of endograft were selected based on diameters measured at the ET level and at the innominate artery (IA) level, with 10% oversizing with respect to the true lumen, but not exceeding the original aortic diameter. The length of the endograft was determined by the distance from the sinotubular junction to IA. RESULTS This study covered 126 TAAD patients with primary ET in ascending aorta, among which, according to the assumed criteria, 48 (38.1%) patients were deemed to be suitable for endovascular treatment. The diameters of ascending aorta from the sinotubular junction to the IA level presented a downward trend, and the proximal diameters differed significantly from distal diameters of the endograft for TAAD (39.9 versus 36.2 mm, P<0.01), implying that the conical endograft might be compatible with the ascending pathology. In the ascending aorta, lengths of the endograft should be 50, 60, 70, 80, and 90 mm in five (10.4%), 22 (45.9%), 13 (27.1%), six (12.5%), and two (4.2%) patients, respectively. CONCLUSION In this selected number of Chinese patients, the suitability of endovascular repair has been demonstrated based on the CT imaging. Shorter, larger, and bare spring-free conical endografts were preferred in the ascending aortic pathology.
منابع مشابه
Late lumen loss in thoracic aortic end graft after endovascular procedure of a traumatic pseudoaneurysm
We report the case of a 23-year-old woman who died due to endograft stenosis 20 months after thoracic endovascular aortic repair. The patient presented with the pseudocoarctation syndrome. Although angioplasty of stenosis endograft was successfully performed, severe metabolic complications were lethal.
متن کاملOpen Conversion for Type A Ascending Aortic Dissection after Thoracic Endovascular Aortic Repair by the Chimney Graft Technique.
An 83-year-old man with aortic arch aneurysm underwent zone 0 thoracic endovascular aortic repair (TEVAR) by the chimney graft technique with two supra-aortic arch debranching grafts and developed subacute type A ascending aortic dissection. We performed emergency open conversion with circulatory arrest under deep hypothermia. The tip of the chimney graft (around the sino-tubular junction in th...
متن کاملCase Report of an Endovascular Repair of a Residual Type A Dissection Using a Not CE Not FDA-Approved Najuta Thoracic Stent Graft System
This report describes an endovascular repair of a residual type A dissection using a medical device that is not marked by european conformity (CE) or Food and Drug Administration (FDA).The patient underwent ascending aortic surgery for acute type A dissection. The 2-year angio-computed tomography demonstrated patency of the residual false lumen with evolution into a 6 cm aneurysm, the extension...
متن کاملChallenges of “Reverse” Aortic Arch Debranching for Repair of the Ascending Aorta by Thoracic Endovascular Aortic Repair
INTRODUCTION Ascending aortic pathology presents a unique challenge for treatment by thoracic endovascular aortic repair (TEVAR), because of lack of adequate endograft landing zones. This report describes a unique "reverse" extra-anatomical aortic arch debranching procedure performed to enable TEVAR of the ascending aorta. REPORT A 71-year-old male presented with a large ascending aortic pseu...
متن کاملExternalized Guidewires to Facilitate Fenestrated Endograft Deployment in the Aortic Arch
PURPOSE To describe a precannulated fenestrated endograft system utilizing externalized guidewires to facilitate aortic arch endovascular repair and to report its use in 2 patients with challenging anatomy. TECHNIQUE For distal arch repair, a fenestration for the left subclavian artery (LSA) is made onsite in a standard thoracic endograft tailored to the patient anatomy; it is precannulated w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -
تاریخ انتشار 2016