Enhancing Fracture and Wear Resistance of Dentures/Overdentures Utilizing Digital Technology: A Case Series Report.

نویسندگان

  • Ahmed Afify
  • Stephan Haney
چکیده

Since it was first introduced into the dental world, computer-aided design/computer-aided manufacturing (CAD/CAM) technology has improved dramatically in regards to both data acquisition and fabrication abilities. CAD/CAM is capable of providing well-fitting intra- and extraoral prostheses when sound guidelines are followed. As CAD/CAM technology encompasses both surgical and prosthetic dental applications as well as fixed and removable aspects, it could improve the average quality of dental prostheses compared with the results obtained by conventional manufacturing methods. The purpose of this article is to provide an introduction into the methods in which this technology may be used to enhance the wear and fracture resistance of dentures and overdentures. This article will also showcase two clinical reports in which CAD/CAM technology has been implemented.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enhancing Wear Resistance of Squeeze Cast AC2A Aluminum Alloy

The effect of squeeze casting process parameters on wear behavior of AC2A aluminium alloy was primarily investigated in this experimental study. Five process parameters, namely squeeze pressure, pouring temperature, die temperature, die material and compression time, each at four levels were chosen and sixteen experimental runs based on L16 orthogonal array were performed. From analysis of vari...

متن کامل

Prospective cohort pilot study of 2-visit CAD/CAM monolithic complete dentures and implant-retained overdentures: Clinical and patient-centered outcomes.

STATEMENT OF PROBLEM Presently, no studies have evaluated clinical outcomes or patient-centered outcomes for complete dentures fabricated with computer-aided design and computer aided manufacturing (CAD/CAM) technology. PURPOSE The purpose of this prospective cohort pilot study was to evaluate the clinical and patient-centered outcomes for CAD/CAM monolithic dentures fabricated in 2 visits. ...

متن کامل

Repair of a fractured implant overdenture gold bar: A clinical and laboratory technique report

This clinical report explains a convenient, efficient, yet effective alternative for management of fractured substructure cast bars for implant-retained overdentures. The technique allows the fracture to be repaired at low cost and short time without remaking the substructure and the denture and further allowing the patient to keep their denture. The report sketches the clinical and laboratory ...

متن کامل

Patient responses to dental implant-retained mandibular overdenture therapy: a 6-year clinical study.

BACKGROUND The purpose of this study was to record subjective patient experiences with respect to the surgical placement of dental implants and the functioning of mandibular implant-retained overdentures versus conventional dentures. METHODS Completely edentulous patients (n = 56) unable to wear a conventional mandibular complete denture were each treated with 4 one-stage titanium plasma spra...

متن کامل

Root-supported overdentures associated with temporary immediate prostheses--a case-report.

Complete denture fabrication can be a treatment challenge for many dentists, especially when the patient has remaining teeth. So, planning for use of clinical alternatives to improve the treatment prognosis and to enable greater comfort to patient must be considered. This case report describes the use of remaining roots to aid in the stability, support and retention of root-supported overdentur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of prosthodontics : official journal of the American College of Prosthodontists

دوره 25 6  شماره 

صفحات  -

تاریخ انتشار 2016