Critical flicker fusion test of potential vision.

نویسندگان

  • Hema Shankar
  • Konrad Pesudovs
چکیده

PURPOSE To continue developing a potential vision test based on the critical flicker fusion (CFF) phenomenon by using a brighter stimulus and optimizing its size. SETTING Flinders Eye Centre, Flinders Medical Centre, Flinders University, Bedford Park, South Australia, Australia. METHODS In a prospective nonrandomized study, 225 participants were assigned to 1 of 4 groups: normal, media opacity only, retinal/neural disease only, and cataract plus retinal/neural disease. Participants were recruited if they were 20 years or older but were excluded if they had a neurological disorder or medication known to affect CFF. The CFF thresholds were measured for 3 stimulus sizes: 0.5 degree, 1.0 degree, and 1.5 degrees. Discrimination between groups was tested by analysis of variance and receiver operating characteristic analysis. The relationship between visual acuity and CFF in eyes without media opacity was determined by linear regression and used to predict visual outcomes in 23 eyes having cataract surgery. RESULTS The mean age of the 225 participants was 71.4 years +/- 13.2 (SD); 134 (59.8%) were women. The normal group had 41 participants, and the other 3 groups had 61 participants each. Critical flicker fusion thresholds were reduced in retinal/neural disease but resistant to image degradation from media opacity. The 1.5-degree stimulus had 88% sensitivity and 90% specificity for discriminating groups. Visual acuity after cataract surgery was accurately predicted within +/-1 line in 43% of eyes, +/-2 lines in 83%, and +/-3 lines in 100%. All eyes with poor visual acuity (>0.50 logMAR) or dense cataract (>4.0 Lens Opacities Classification System III) were predicted within +/-2 lines. CONCLUSIONS The CFF phenomenon effectively discriminated between subjects with and without retinal/neural disease and accurately predicted visual outcome after cataract surgery. The use of a brighter stimulus enhanced performance in cases of dense media opacity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a critical flicker/fusion frequency test for potential vision testing in media opacities.

PURPOSE To determine whether critical flicker/fusion (CFF) thresholds fulfill the criteria for a potential vision test (PVT) by being unaffected by media opacity yet affected by retinal disease. METHODS CFF thresholds for three different stimulus sizes (0.5, 1.0, and 1.5 degrees ) were measured in 72 patients (mean age, 78.43 +/- 7.07 years) comprising 31 subjects with media opacity, 21 with ...

متن کامل

An ecological correlate of critical flicker-fusion frequencies for some Anolis lizards.

The maximum critical flicker-fusion frequency (CFF) was determined for seven species of anoline lizards. The congeners showed a wide range of CFF values from 26 to 42. These values correlated with the general level of insolation in each species’ microhabitat. such that the brighter the habitat. the higher the CFF.

متن کامل

The nitroglycerin-flicker test.

The nitroglycerin-flicker test, as suggested and modified by Krasno and Ivy, has been used to test normal individuals and patients with a variety of cardiovascular diseases. The hypothesis that this test would serve as an index of the presence of vascular disease or spasm elsewhere in the body than the retina was explored. These studies have failed to justify the drawing of conclusions based on...

متن کامل

Nonlinear combination of luminance excursions during flicker, simultaneous contrast, afterimages and binocular fusion

The changes in apparent brightness or color, induced into a test spot by a surround, can be greatly enhanced either by flickering the test spot between two luminances, or by binocularly fusing a pair of test spots of different luminances. Simultaneous contrast, in which a white surround makes a grey spot look darker, is greatly enhanced if the spot (not the surround) flickers between black and ...

متن کامل

Significance of the nitroglycerin-flicker fusion response in normal subjects and patients with cardiovascular disease.

The Krasno-Ivy nitroglycerin-flicker fusion test was carried out in normal persons, and in patients with arterial hypertension and/or coronary disease. A positive test was obtained more often in patients with cardiovascular abnormalities than in normal individuals. In the former group the frequency of negative results and the inconstancy of response to multiple tests indicate the unrelia-bility...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 33 2  شماره 

صفحات  -

تاریخ انتشار 2007