Operative use of a vacuum-formed splint in the reduction of displaced mandibular fractures.

نویسندگان

  • Andrea N Beech
  • Jeremy N Farrier
چکیده

e report a simple and effective way of reducing a rossly-displaced, bilaterally-fractured mandible with a acuum-formed thermoplastic splint. This allowed simple nd precise reduction and enabled plating of the fracture sites xtraorally. The use of the dental occlusion as a guide is one of the most asic concepts in the management of mandibular fractures, nd operative maxillomandibular fixation (MMF) is vital to he surgeon during reduction and immobilisation. Methods nclude MMF with cortical bone screws,1 arch bars,2,3 and hermoforming plates.4 Severely displaced mandibular fractures can be difficult to educe effectively, particularly in patients with several fracures and missing teeth, with or without poor periodontal ealth, and options for MMF are limited. Lloyd et al5 described the management of a unilateral racture of the mandibular condyle with a vacuum-formed plint. We altered this and applied it to the operative MMF f a patient with a grossly displaced, bilateral mandibular racture. A 31-year-old woman was kicked in the face by a raceorse. She presented with grossly displaced fractures of er right mandibular angle and left mandibular parasymhysis. Her oral hygiene was poor, and she had acute lcerative gingivitis. Her medical history was not releant. An orthopantogram and posteroanterior mandibular radioraphs were taken followed by a computed tomogram with

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Conservative Method for Treating Severely Displaced Pediatric Mandibular Fractures: An Effective Alternative Technique

Pediatric mandibular fractures have been successfully managed in various ways. The use of a lingual splint is an option. This article presents a 4-year old boy who was treated by an alternative conservative method with a combination of an arch bar plus a lingual splint, circum-mandibular wiring and IMF for the reduction, stabilization and fixation of a severely displaced bilateral man‌dibular b...

متن کامل

Open reduction and internal fixation of mandibular fracture in an 11-month-old infant: a case report

Mandibular fractures in infants are rare. This case report describes management of a mandibular fracture in an 11-month-old infant using a microplate and screws with open reduction. The surgical treatment was successful. Because the bone fragments were displaced and only the primary incisors had erupted, conservative treatment, such as an acrylic splint and circummandibular wiring, was not reco...

متن کامل

Re-displacement of extraphyseal distal radius fractures following initial reduction in skeletally immature patients--can it be prevented?

PURPOSE The purpose of this study was to evaluate the efficacy of sugar tongs splints to maintain reduction of pediatric distal radius and distal both bones forearm fractures compared to acute casting. MATERIALS AND METHODS The trauma database of an urban level-one trauma center was queried for skeletally immature patients who had sustained a displaced extraphyseal distal radius fracture. Inc...

متن کامل

The use of vacuum-formed splints for temporary intermaxillary fixation in the management of unilateral condylar fractures.

We report a simple, effective method of managing displaced unilateral condylar fractures with occlusal disruption using vacuum-formed thermoplastic foil splints with bonded wire cleats. The cleats enable intermaxillary fixation in the form of orthodontic elastics to be used, which guide then maintain the occlusion in centric relation. A case is presented in which this technique was used success...

متن کامل

A Technique to Guide and Measure the Reduction of a Processed Mandibular Complete Denture for Resilient Soft Liner

A resilient soft liner (RSL) has been used in processed complete dentures but controlling its thickness has always been a challenge because of uneven reduction of the denture’s intaglio surface. Use of a thermoplastic vacuum-formed template and an endodontic K-file, as guides, for the reduction of a processed mandibular complete denture to receive RSL is described in the present report. A proce...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The British journal of oral & maxillofacial surgery

دوره 54 2  شماره 

صفحات  -

تاریخ انتشار 2016