Comparative values of gated blood-pool SPECT and CMR for ejection fraction and volume estimation.

نویسندگان

  • Louis Sibille
  • Fayçal Ben Bouallegue
  • Aurélie Bourdon
  • Antoine Micheau
  • Hélène Vernhet-Kovacsik
  • Denis Mariano-Goulart
چکیده

OBJECTIVE Gated blood-pool single-photon emission computed tomography (GBPS) was compared with cardiac magnetic resonance (CMR) for the measurement of left ventricular (LV) and right ventricular (RV) ejection fractions (EF) and volumes [end-diastolic volume (EDV) or end-systolic volume (ESV)] in a mixed population. METHODS Thirty patients (70% men; mean age: 61±14 years) referred for various symptoms or heart diseases, predominantly ischemic, were included. GBPS data were analyzed using segmentation software described earlier based on the watershed algorithm. CMR images were acquired for both ventricles at the same time using a steady-state-free precession sequence and short-axis views. No compensation for papillary muscles was used. LVEF and RVEF and volumes were assessed with GBPS and CMR and were compared. RESULTS LVEF and volumes were correlated (P<0.001). The difference in LVEF between GBPS and CMR was not significant (P=0.063). The limits of agreement were close for LVEF (-11 to 15%) and wider for LV volumes (-82 to 11 ml for EDV and -52 to 15 ml for ESV), with higher volume values obtained with CMR (mean differences of 36±24 ml for EDV and 19±17 ml for ESV). The RVEF and volumes assessed by GBPS and CMR were correlated (P<0.001). The difference in RVESV between GBPS or CMR was not significant (P=0.136). The limits of agreement were relatively close for all RV parameters (-15 to 8% for EF; -44 to 22 ml for EDV, and -25 to 21 ml for ESV). In 24 patients without valvulopathy or shunt, the difference between LV stroke volume and RV stroke volume was lower with GBPS than with CMR (9±14 ml and 18±13 ml, respectively, with P=0.027). CONCLUSION GBPS is a simple and widely available technique that can assess both LVEF and RVEF, and volumes with slight differences compared with CMR.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normal values of left ventricular functional indices in gated 99mTc-MIBI myocardial perfusion SPECT

  Introduction: Although left ventricular(LV) function parameters measured by gated myocardial perfusion SPECT (GSPECT) have been validated, experimental data have revealed that the calculated the LV function parameters using GSPECT are affected by patient populations as well as particular acquisition and processing conditions. We tried to determine the normal values ...

متن کامل

Evaluation of left and right ventricular ejection fraction and volumes from gated blood-pool SPECT in patients with dilated cardiomyopathy: comparison with cardiac MRI.

UNLABELLED This prospective study evaluated the accuracy of electrocardiogram-gated blood-pool SPECT (GBPS) for the assessment of left ventricular (LV) and right ventricular (RV) ejection fraction (EF), end-diastolic volume (EDV), and end-systolic volume (ESV) in patients with dilated cardiomyopathy (DCM), using cardiac magnetic resonance (CMR) imaging as the reference standard. METHODS Thirt...

متن کامل

Dipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings

  Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...

متن کامل

Evaluation of the Left Ventricular Ejection Fraction with Gated IQ-SPECT Myocardial Perfusion Imaging.

UNLABELLED The aim of this study was to evaluate the assessment of the left ventricular ejection fraction (LVEF) in patients by gated IQ-SPECT. METHODS Twenty-eight patients were examined using gated (99m)Tc-sestamibi IQ-SPECT. Two different reconstruction datasets were created using the same projection data. The number of iterations, subsets, and gaussian filtering were based on 2 different ...

متن کامل

[Reproducibility of measurements of left ventricular function with gated myocardial perfusion SPECT and comparison with blood pool radionuclide ventriculography].

INTRODUCTION AND OBJECTIVE This study was designed to evaluate the reproducibility of ejection fraction (EF) and ventricular volume measurements obtained with single photon emission computed tomography (gated-SPECT), and to assess the correlation between EF values obtained with this method and blood pool planar radionuclide ventriculography. PATIENTS AND METHOD A total of 55 patients were inc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Nuclear medicine communications

دوره 32 2  شماره 

صفحات  -

تاریخ انتشار 2011