Paravaginal defects: a comparison of clinical examination and 2D/3D ultrasound imaging.
نویسندگان
چکیده
BACKGROUND Paravaginal defects are often assumed to be the underlying anatomical abnormality in anterior compartment descent. Neither clinical examination nor ultrasound assessment are generally accepted diagnostic modalities. AIMS To compare clinical examination and translabial 3D ultrasound in the detection of such defects. METHODS Fifty-nine women without previous prolapse or incontinence surgery were seen prospectively. Clinical and ultrasound assessments were carried out in blinded fashion. 3D translabial ultrasound was undertaken after voiding and supine. Volumes were acquired at rest, on Valsalva and on levator contraction. Loss of paravaginal support ('tenting') in the axial plane was taken to signify paravaginal defects. RESULTS Paravaginal defects were reported clinically in 14 cases on the left (24%), 19 times on the right (32%). Two 3D ultrasound examinations did not yield satisfactory volumes, leaving 57 for analysis. Neither midsagittal nor coronal views yielded data that correlated with clinical assessments. In the axial plane there was absence of tenting at rest in 32/57 (57%) patients, but this did not correlate with clinical findings. Loss of tenting on Valsalva was observed less often (21/57, 37%) and was weakly associated with clinically observed lateral defects (P = 0.036). CONCLUSIONS Pelvic floor ultrasound in midsagittal, axial or coronal planes does not correlate well with clinical assessment for paravaginal defects. This could be due to poor clinical assessment technique or limitations of the ultrasound method. On the other hand, paravaginal defects may be uncommon or clinically irrelevant. On present knowledge, the paravaginal defect has to be regarded as an unproven concept.
منابع مشابه
Ultrasonographic Volumetry of the Canine Thyroid Gland: A Comparison of 2D, 3D Ultrasonography and Real Gland Volume
Objective: to compare the estimated thyroid volume, as determined by two-dimensional (2D) and three-dimensional (3D) ultrasonography, with real volume. Design: Descriptive Study Animals: A total of 7 mixed breed dogs Procedures: On 2D ultrasound, the thyroid volume is estimated by the ellipsoid equation and on 3D ultrasound; it is estimated by outlining the boundaries of the thyroid lobe in ...
متن کاملAdaptive beamforming in row-column addressed arrays for 3D ultrasound imaging
In recent years, to reduce the complexity of implementation, the use of 2D arrays with restricted row-column addressing has been considered for 3D ultrasound imaging. In this paper, two methods of adaptive beamforming based on the minimum variance method are represented in such a way that the computational load is much less than using the full adaptive beamforming method. In both proposed metho...
متن کاملAn overview of clinical PET/CT
This article is intended to provide an overview of various aspects of clinical PET/CT. These include discussions of: (i) Important areas of clinical application; (ii) Opportunities in clinical research; (iii) Scanner and operating-mode considerations (e.g. BGO vs. LSO, LYSO or GSO scanners, 2D vs. 3D imaging). (iv) Study-specific considerations (e.g. patient preparation and positioning is...
متن کاملEvaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT
Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...
متن کاملThree-dimensional transvaginal ultrasound: clinical implementation in assessing uterine cavity
Background: Three-dimensional transvaginal ultrasonography (3D TVS) represents a new technique of imaging and provides a unique diagnostic tool for non-invasive examination of the uterine morphology and diagnosis of congenital uterine anomalies. In this study the clinical value of 3D TVS in diagnosis of uterine cavity abnormalities were evaluated. Methods: A prospective of diagnostic accuracy s...