Parallel imaging of knee cartilage at 3 Tesla.
نویسندگان
چکیده
PURPOSE To evaluate the feasibility and reproducibility of quantitative cartilage imaging with parallel imaging at 3T and to determine the impact of the acceleration factor (AF) on morphological and relaxation measurements. MATERIALS AND METHODS An eight-channel phased-array knee coil was employed for conventional and parallel imaging on a 3T scanner. The imaging protocol consisted of a T2-weighted fast spin echo (FSE), a 3D-spoiled gradient echo (SPGR), a custom 3D-SPGR T1rho, and a 3D-SPGR T2 sequence. Parallel imaging was performed with an array spatial sensitivity technique (ASSET). The left knees of six healthy volunteers were scanned with both conventional and parallel imaging (AF = 2). RESULTS Morphological parameters and relaxation maps from parallel imaging methods (AF = 2) showed comparable results with conventional method. The intraclass correlation coefficient (ICC) of the two methods for cartilage volume, mean cartilage thickness, T1rho, and T2 were 0.999, 0.977, 0.964, and 0.969, respectively, while demonstrating excellent reproducibility. No significant measurement differences were found when AF reached 3 despite the low signal-to-noise ratio (SNR). CONCLUSION The study demonstrated that parallel imaging can be applied to current knee cartilage quantification at AF = 2 without degrading measurement accuracy with good reproducibility while effectively reducing scan time. Shorter imaging times can be achieved with higher AF at the cost of SNR.
منابع مشابه
Water fat separation using the single acquisition "sandwich" type 3-point Dixon method to optimize knee joint scans.
In this paper, we tried to evaluate the effect of water-fat separation on and to optimize the scan condition of the newly developed "Sandwiched" 3-point Dixon method at 0.35 Tesla (T), for knee joint imaging. Using a 0.35T superconductive open magnet system with a solenoid type knee coil, one male and two female normal volunteers (27-37 y.o.) underwent knee joint imaging. Each sequence provided...
متن کاملAccuracy of cartilage-specific 3-Tesla 3D-DESS magnetic resonance imaging in the diagnosis of chondral lesions: comparison with knee arthroscopy.
BACKGROUND Arthroscopy is considered as "the gold standard" for the diagnosis of traumatic intraarticular knee lesions. However, recent developments in magnetic resonance imaging (MRI) now offer good opportunities for the indirect assessment of the integrity and structural changes of the knee articular cartilage. The study was to investigate whether cartilage-specific sequences on a 3-Tesla MRI...
متن کاملUsefulness of using laser-induced photoacoustic measurement and 3.0 Tesla MRI to assess knee cartilage damage: a comparison study
BACKGROUND T2 mapping is an MRI method particularly reflective of the collagen arrangement in the cartilage, and diffusion tensor (DT) imaging captures the diffusion of water molecules. Laser-induced photoacoustic measurement (LIPA) makes it possible to assess not only the thickness of the cartilage layer but also its viscoelastic properties. By assessing cartilage damage assessment using LIPA ...
متن کاملLong-term and short-term reproducibility of T2 relaxation time in human knee cartilage
INTRODUCTION T2 relaxation time of articular cartilage has been reported to reflect the orientation and concentration of collagen fibrils [1-2]. The reproducibility of T2 in human patellar cartilage has been reported to be close to 5% [3]. However, the patellar cartilage is the thickest one in the knee, and the reproducibility in other articular surfaces has not been studied earlier. In this st...
متن کاملIn-Vitro Evaluation of Pre- and Post-Compression States of Human Articular Cartilage Using MRI at 3 Tesla
The purpose of this study was to evaluate changes of several MR parameters (T1, T2 and ADC) before and after compression in human cartilage samples using unique microimaging compression system. Cartilage samples were prepared from joints of 10 patients, who underwent a total knee joint replacement. Study was performed on a Bruker 3T Medspec whole-body scanner (Bruker, Ettlingen, Germany) using ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 26 4 شماره
صفحات -
تاریخ انتشار 2007