Total shoulder arthroplasty biomechanics: a study of the forces and strains at the glenoid component.

نویسندگان

  • A R Karduna
  • G R Williams
  • J P Iannotti
  • J L Williams
چکیده

The objective of this study was to examine how changes in glenohumeral joint conformity and loading patterns affected the forces and strains developed at the glenoid. After removal of soft tissue (muscles, ligaments, and labrum), force-displacement data were collected for both natural and prosthetically reconstructed joints. Joints were shown to develop higher forces for a given translation as joint conformity increased. A rigid body model of joint contact forces was used to determined the so-called effective radial mismatch of each joint. For the purposes of this study, the effective radial mismatch is defined as the mismatch required for a rigid body joint to have the same force-displacement relationship as the joint in question. This parameter is an indication of the deformation at the articular surface. The effective radial mismatch dramatically increased with increasing medial loads, indicating that under physiological loads, the effective radial mismatch of a joint is much greater than its measured mismatch at no load. This increase in effective mismatch as medial loads were increased was found to be threefold greater in cartilaginous joints than in reconstructed joints. Rosette strain gages positioned at the midlevel of the glenoid keel in the reconstructed joints revealed that anterior/posterior component loading leads to fully reversible cyclic keel strains. The highest compressive strains occurred with the head centered in the glenoid, and were larger for nonconforming joints (epsilon = 0.23 percent). These strains became tensile just before rim loading and were greater for conforming joints (epsilon = 0.15 percent). Although recorded peak strains are below the yield point for polyethylene, the fully reversed cyclic loading of the component in this fashion may ultimately lead to component toggling and implant failure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Revision of Anatomic Total Shoulder Arthroplasty to Hemiarthroplasty: Does it work?

Background: The projected increase in revision shoulder arthroplasty has increased interest in the outcomes of theseprocedures. Glenoid component removal and conversion to a hemiarthroplasty (HA) is an option for aseptic glenoidloosening after anatomic total shoulder arthroplasty (aTSA).Methods: We identified patients who had undergone revision shoulder arthroplasty over a 15-...

متن کامل

Comparison of Asymmetric Reaming versus a Posteriorly Augmented Component for Posterior Glenoid Wear and Retroversion: A Radiographic Study

Background: Managing posterior glenoid wear and retroversion remains a challenge in shoulder arthroplasty.Correcting glenoid version through asymmetric reaming (AR) with placement of a standard glenoid component and theuse of posteriorly augmented glenoid (PAG) components are two methods used to address this problem. Our objectiveis to report the radiographic outcomes of patie...

متن کامل

The glenoid in shoulder arthroplasty.

Total shoulder arthroplasty is a common treatment for glenohumeral arthritis. One of the most common failure modes of total shoulder arthroplasty is glenoid loosening, causing postoperative pain, limitation of function, and potentially, the need for revision surgery. The literature has devoted considerable attention to the design of the glenoid component; efforts to better understand the biomec...

متن کامل

Genetic and biomechanical determinants of glenoid version: implications for glenoid implant placement in shoulder arthroplasty.

SUMMARY The universally accepted method of measuring glenoid version to determine proper alignment of the glenoid component during total shoulder arthroplasty does not account for the complex and variable relationship of the glenoid vault with the scapular body. Existing evidence indicates that the glenoid and the scapular body development are controlled by independent genetic and biomechanical...

متن کامل

Analysis of reverse total shoulder joint forces and glenoid fixation.

Reverse total shoulder arthroplasty (rTSA) implants are intended to restore stability and function to shoulders with rotator cuff deficiency. The implant consists of a glenosphere projecting from a glenoid baseplate and articulating in a socket at the proximal end of a humeral component. Despite the demonstrated clinical efficacy, little information is available regarding the joint forces about...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanical engineering

دوره 120 1  شماره 

صفحات  -

تاریخ انتشار 1998