Improved measurement linearity and precision for AMCW time-of-flight range imaging cameras.

نویسندگان

  • Andrew D Payne
  • Adrian A Dorrington
  • Michael J Cree
  • Dale A Carnegie
چکیده

Time-of-flight range imaging systems utilizing the amplitude modulated continuous wave (AMCW) technique often suffer from measurement nonlinearity due to the presence of aliased harmonics within the amplitude modulation signals. Typically a calibration is performed to correct these errors. We demonstrate an alternative phase encoding approach that attenuates the harmonics during the sampling process, thereby improving measurement linearity in the raw measurements. This mitigates the need to measure the system's response or calibrate for environmental changes. In conjunction with improved linearity, we demonstrate that measurement precision can also be increased by reducing the duty cycle of the amplitude modulated illumination source (while maintaining overall illumination power).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Evaluation of Time-of-flight Range Cameras for Close Range Metrology Applications

Time-of-flight range cameras are an emerging technology that produces a digital photo or video like output in which every pixel contains both intensity and distance information. Typical currently available off-the-shelf range imaging cameras offer spatial resolutions of up to 40 k-pixels, distance measurement precision of less than 1 cm, and accuracy of a few centimetres. These specifications s...

متن کامل

Quantified, Interactive Simulation of AMCW ToF Camera Including Multipath Effects

In the last decade, Time-of-Flight (ToF) range cameras have gained increasing popularity in robotics, automotive industry, and home entertainment. Despite technological developments, ToF cameras still suffer from error sources such as multipath interference or motion artifacts. Thus, simulation of ToF cameras, including these artifacts, is important to improve camera and algorithm development. ...

متن کامل

Multiple range imaging camera operation with minimal performance impact

Time-of-flight range imaging cameras operate by illuminating a scene with amplitude modulated light and measuring the phase shift of the modulation envelope between the emitted and reflected light. Object distance can then be calculated from this phase measurement. This approach does not work in multiple camera environments as the measured phase is corrupted by the illumination from other camer...

متن کامل

New approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras

Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...

متن کامل

Geo-referenced mapping using an airborne 3D time-of-flight camera

This paper presents the first experience of a close range bird’s eye view photogrammetry with range imaging (RIM) sensors for the real time generation of high resolution geo-referenced 3D surface models. The aim of this study was to develop a mobile, versatile and less costly outdoor survey methodology to measure natural surfaces compared to the terrestrial laser scanning (TLS). Two commercial ...