Composite infrared bolometers with Si3N4 micromesh absorbers.

نویسندگان

  • P D Mauskopf
  • J J Bock
  • H Del Castillo
  • W L Holzapfel
  • A E Lange
چکیده

We report the design and performance of 300-mK composite bolometers that use micromesh absorbers and support structures patterned from thin films of low-stress silicon nitride. The small geometrical filling factor of the micromesh absorber provides 20x reduction in heat capacity and cosmic ray cross section relative to a solid absorber with no loss in IR-absorption efficiency. The support structure is mechanically robust and has a thermal conductance, G < 2 x 10(-11) W/K, which is four times smaller than previously achieved at 300 mK. The temperature rise of the bolometer is measured with a neutron transmutation doped germanium thermistor attached to the absorbing mesh. The dispersion in electrical and thermal parameters of a sample of 12 bolometers optimized for the Sunyaev-Zel'dovich Infrared Experiment is +/-7% in R (T), +/-5% in optical efficiency, and +/-4% in G.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microfabrication of silicon–nitride micromesh bolometric detectors for planck high frequency instrument

The high frequency instrument ~HFI! on the National Aeronautics and Space Administration/ European Space Agency Planck Surveyor, scheduled for launch in 2007, will map the entire sky in six frequency bands ranging from 100 to 857 GHz to probe cosmic microwave background anisotropy and polarization with angular resolution ranging from 98 to 58. The HFI focal plane will contain 48 silicon–nitride...

متن کامل

Antenna-coupled Bolometer Arrays for Astrophysics

We are developing arrays of feedhorn-coupled, silicon nitride micromesh (‘spider web’) bolometers for the ESA/NASA Planck Surveyor and Herschel Space Observatory for millimeter to far-infrared wavelengths. These detector systems realize high end-to-end optical efficiency, essentially fill the available focal surface, and achieve background-limited sensitivity. The Planck/HFI detectors in partic...

متن کامل

Silicon nitride Micromesh Bolometer Array for Submillimeter Astrophysics.

We present the design and performance of a feedhorn-coupled bolometer array intended for a sensitive 350-mum photometer camera. Silicon nitride micromesh absorbers minimize the suspended mass and heat capacity of the bolometers. The temperature transducers, neutron-transmutation-doped Ge thermistors, are attached to the absorber with In bump bonds. Vapor-deposited electrical leads address the t...

متن کامل

Chapter 3 . High - Frequency ( > 100 GHz ) Electronic Devices

Professor Hu's laboratory is equipped with various millimeter-wave and infrared sources which can generate coherent and incoherent radiation up to 30 THz. These include Gunn oscillators at W-band frequencies (75-110 GHz); a frequency doubler, tripler, and quadrupler using Schottky diodes at 200, 300, and 400 GHz; an optically pumped farinfrared laser which generates coherent radiation up to 8 T...

متن کامل

Ideal Integrating Bolometer

A bolometer consists of a thermometer with heat capacity C mounted on an absorbing substrate, weakly coupled to a bath at temperature T0 via a thermal conductance G ( Figure 1 ). Resistive bolometers (including both composite and transition-edge bolometers) use the temperature dependence of a resistive element to measure the infrared signal incident on the absorber. In steady-state operation, t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied optics

دوره 36 4  شماره 

صفحات  -

تاریخ انتشار 1997