Validity of treadmill- and track-based individual calibration methods for estimating free-living walking speed and VO2 using the Actigraph accelerometer

نویسندگان

  • Anthony Barnett
  • Ester Cerin
  • Corneel Vandelanotte
  • Aya Matsumoto
  • David Jenkins
چکیده

BACKGROUND For many patients clinical prescription of walking will be beneficial to health and accelerometers can be used to monitor their walking intensity, frequency and duration over many days. Walking intensity should include establishment of individual specific accelerometer count, walking speed and energy expenditure (VO2) relationships and this can be achieved using a walking protocol on a treadmill or overground. However, differences in gait mechanics during treadmill compared to overground walking may result in inaccurate estimations of free-living walking speed and VO2. The aims of this study were to compare the validity of track- and treadmill-based calibration methods for estimating free-living level walking speed and VO2 and to explain between-method differences in accuracy of estimation. METHODS Fifty healthy adults [32 women and 18 men; mean (SD): 40 (13) years] walked at four pre-determined speeds on an outdoor track and a treadmill, and completed three 1-km self-paced level walks while wearing an Actigraph monitor and a mobile oxygen analyser. Speed- and VO2-to-Actigraph count individual calibration equations were computed for each calibration method. Between-method differences in calibration equation parameters, prediction errors, and relationships of walking speed with VO2 and Actigraph counts were assessed. RESULTS The treadmill-calibration equation overestimated free-living walking speed (on average, by 0.7 km · h(-1)) and VO2 (by 4.99 ml · kg(-1) · min(-1)), while the track-calibration equation did not. This was because treadmill walking, from which the calibration equation was derived, produced lower Actigraph counts and higher VO2 for a given walking speed compared to walking on a track. The prediction error associated with the use of the treadmill-calibration method increased with free-living walking speed. This issue was not observed when using the track-calibration method. CONCLUSIONS The proposed track-based individual accelerometer calibration method can provide accurate and unbiased estimates of free-living walking speed and VO2 from walking. The treadmill-based calibration produces calibration equations that tend to substantially overestimate both VO2 and speed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Concurrent validity of the PAM accelerometer relative to the MTI Actigraph using oxygen consumption as a reference.

The purpose of this study was to examine the concurrent validity of the Personal Activity Monitor (PAM) accelerometer relative to the Actigraph accelerometer using oxygen consumption as a reference, and to assess the test-retest reliability of the PAM. Thirty-two fit, normal weight adults (aged 21-54) performed two activities, treadmill walking and stair walking, while wearing the PAM, the Acti...

متن کامل

Validation of Physical Activity Tracking via Android Smartphones Compared to ActiGraph Accelerometer: Laboratory-Based and Free-Living Validation Studies

BACKGROUND There is increasing interest in using smartphones as stand-alone physical activity monitors via their built-in accelerometers, but there is presently limited data on the validity of this approach. OBJECTIVE The purpose of this work was to determine the validity and reliability of 3 Android smartphones for measuring physical activity among midlife and older adults. METHODS A labor...

متن کامل

Convergent validity of 3 low cost motion sensors with the ActiGraph accelerometer.

BACKGROUND This study evaluated the utility of several lower cost physical activity (PA) assessment instruments for detecting PA volume (steps) and intensity (time in MVPA or activity time) using convergent methods of assessment. METHODS Participants included 26 adults (9 male) age 27.3 ± 7.1 years with a BMI of 23.8 ± 2.8 kg/m2. Instruments evaluated included the Omron HJ-151 (OM), New Lifes...

متن کامل

Validity of the Actical accelerometer step-count function.

PURPOSE To assess the validity of the new Actical accelerometer step count function. METHODS Actical step counts were compared according to two criterion standards. 1) Eight Acticals were assessed using a mechanical shaker table under six different testing conditions. 2) Thirty-eight volunteers (aged 9-59 yr) wore eight Acticals and eight Actigraphs during treadmill walking (50 and 83 m.min(-...

متن کامل

Comparison of three models of actigraph accelerometers during free living and controlled laboratory conditions.

The aim of this study was to compare the outputs of three commonly used uniaxial Actigraph models (Actitrainer, 7164 and GT1M) under both free-living and controlled laboratory conditions. Ten adults (mean age = 24.7±1.1 years) wore the three Actigraph models simultaneously during one of day free-living and during a progressive exercise protocol on a treadmill at speeds between 1.5 and 5.5 miles...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2015