Discrepancy between anatomical axis and stem position of various femoral components in Japanese.

نویسندگان

  • M Ueno
  • Ken Urabe
  • Mamou Fujita
  • Jun Aikawa
  • Akimasa Kobayashi
  • M Itoman
چکیده

PURPOSE To evaluate the discrepancy between the anatomical axis of the distal femur of Japanese patients and the stem position of 5 types of femoral components. METHODS Lateral radiographs of 12 men and 88 women aged 31 to 83 (mean, 59) years with rheumatoid arthritis were evaluated. The discrepancy between the anatomical axis of the distal femur and the stem position of 5 types of femoral components (Nexgen LCCK, Press-Fit Condylar, Scorpio, Total Stabilizer, and Rotating Hinge) was determined by superimposing the template of each model over each lateral radiograph. RESULTS The anatomical axis varied widely among our patients, as did the stem position of the 5 femoral components. Stems of all 5 femoral components tended to be more posterior than the anatomical axis. The discrepancy was smallest in the Nexgen LCCK, followed by the Press-Fit Condylar components. It was >3 mm in the other 3 models. In 35% of the patients, none of the prosthesis could be placed in an appropriate position. Smaller-size prostheses appear necessary for the Japanese. CONCLUSION The stem position should be an important factor guiding selection of the appropriate model. The currently available femoral components may not be appropriate for the Japanese. Prostheses with appropriately positioned stems for Japanese patients with rheumatoid arthritis should be developed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Single Femoral Component for All Total Hip Replacements Performed by a Trust? Does This Affect Early Clinical and Radiological Outcomes?

Background: Hospitals may be under pressure to implement cost saving strategies regarding prosthesis choice. Thismay involve the use of components which are not the first preference of individual surgeons, or those they have littleexperience with. We aim to examine the effect of standardizing the type of femoral stem used in a single trust, anddetermine whether this is safe practice, particular...

متن کامل

Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population)

    Background: Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational ...

متن کامل

Different References for Valgus Cut Angle in Total Knee Arthroplasty

Background: The valgus cut angle (VCA) of the distal femur in Total Knee Arthroplasty (TKA) is measured preoperativelyon three-joint alignment radiographs. The anatomical axis of the femur can be described as the anatomical axis of thefull length of the femur or as the anatomical axis of the distal half of the femur, which may result in different anglesin some cases. During TKA, the anatomical ...

متن کامل

Porous Femoral Fixation in Total Hip Arthroplasty with Short Anatomical Stem: Radiographic Evaluation

BACKGROUND Hip prostheses with short anatomical stems were designed for metaphyseal fixation and to spare bone stock. We present a study of a short anatomical femoral stem used in all age groups of patients with Dorr A and B type of femora. METHODS We reviewed radiographs of 85 hips in 74 patients who had a cementless total hip arthroplasty with a short anatomical 80 mm femoral stem designed ...

متن کامل

The Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty

Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 18 1  شماره 

صفحات  -

تاریخ انتشار 2010