Accuracy of Component Placement in Robotic-Assisted Total Hip Arthroplasty.

نویسندگان

  • John M Redmond
  • Asheesh Gupta
  • Jon E Hammarstedt
  • Alexandra Petrakos
  • Christine E Stake
  • Benjamin G Domb
چکیده

Robotic-assisted total hip arthroplasty (THA) is a recent platform introduced to decrease the risk of malpositioned components. The goals of this study were to determine whether intraoperative data on robotic-assisted THA acetabular component position accurately predict postoperative radiographic acetabular component position and to determine whether intraoperative data on robotic-assisted THA leg length and offset accurately predict postoperative radiographic leg length and offset data. In 146 patients, pre- and postoperative radiographs and intraoperative component measurements were reported for acetabular inclination, anteversion, leg length change, and offset change. Component position obtained by the robotic system and radiographic data were compared with subgroup analysis for the posterior and direct anterior approaches. The average difference between groups was 3.3°±3.1° for inclination, 2.9°±2.3° for anteversion, 3.0±2.3 mm for leg length change, and 4.0±3.1 mm for change in global offset. Correlation between the robotic system and postoperative radiographs was within 10° for 95.9% of cases for inclination and 99.3% for anteversion. Posterior approach correlation was within 10° for 97.1% of cases for inclination and 100% for anteversion. Anterior approach correlation was within 10° for 92.7% of cases for inclination and 97.6% for anteversion. Intraoperative data on component position obtained from the robotic system compared well with radiographic data on component position. Surgeons must remain vigilant to ensure outliers related to robotic system malfunction do not occur. [Orthopedics. 2016; 39(3):193-199.].

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does Robotic-Assisted Computer Navigation Affect Acetabular Cup Positioning in Total Hip Arthroplasty in the Obese Patient? A Comparison Study.

Obese populations present challenges for acetabular cup placement during total hip arthroplasty (THA). This study examines the accuracy of acetabular cup inclination and version in the obese patient with robotic-assisted computer navigation. A total of 105 patients underwent robotic-assisted computer navigation THA with a posterior approach. Groups were divided on body mass index (BMI, kg/m(2))...

متن کامل

Accuracy of Component Positioning in 2330 Total Hip Arthroplasties: A Comparative Analysis by Surgical Technique and Mode of Guidance

Lewinnek et al described a safe zone of acetabular component placement in Total Hip Arthroplasty (THA) to reduce complications. This safe zone is between 10-30 degrees of version and 30-50 degrees of inclination 1 . Callanan et al. reports only 53% of acetabular cups were within Lewinnek’s Safe Zone of optimal cup placement (62% within the abduction safe zone, 79% within the version safe zone)....

متن کامل

Patient-specific instrumentation improves the accuracy of acetabular component placement in total hip arthroplasty.

AIMS Accurate placement of the acetabular component during total hip arthroplasty (THA) is an important factor in the success of the procedure. However, the reported accuracy varies greatly and is dependent upon whether free hand or navigated techniques are used. The aim of this study was to assess the accuracy of an instrument system that incorporates 3D printed, patient-specific guides design...

متن کامل

Robotic systems in total hip arthroplasty--is the time ripe for a new approach?

The technical aspects of manual total hip arthroplasty are briefly described. The development, technique and technical problems of previous robotic systems in total hip arthroplasty are described with special details of the Robodoc--System. Recent advances regarding the minimally invasive technique of total-hip implantation and navigation are described. The current development of a robotic assi...

متن کامل

Accuracy of Component Positioning in 1980 Total Hip Arthroplasties: A Comparative Analysis by Surgical Technique and Mode of Guidance.

The purpose of this multi-surgeon study was to assess and compare the accuracy of acetabular component placement, leg length discrepancy (LLD), and global offset difference (GOD) between six different surgical techniques and modes of guidance in total hip arthroplasty (THA). A total of 1980 THAs met inclusion criteria. Robotic- and navigation-guided techniques were more consistent than other te...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Orthopedics

دوره 39 3  شماره 

صفحات  -

تاریخ انتشار 2016