Background There is no evidence from randomized trials for the benefit of routine non-compliant balloon (NCB) post-dilation after stent deployment. Despite being the gold standard, intravascular ultrasound is infrequently performed due to time and cost constraints and a suitable alternative technology is required for routine assessment of stent expansion. The purpose of this study was to assess the contribution of NCB post-dilation in optimizing contemporary stents by using digital stent enhancement (DSE). Methods We treated 120 patients with stent insertion and assessed the stents with DSE before and after NCB use. Optimal expansion was defined as the minimum stent diameter (MSD) ≥ 90% of the nominal stent diameter, an adaptation of the MUSIC and POSTIT trial criteria. Stent deployment was performed at 12 atm pressure followed by routine NCB post-dilation at ≥ 14 atm. Results The mean reference diameter on QCA was 2.75 mm (SD 0.63) and mean stent diameter was 3.15 mm (SD 0.46). At a mean stent deployment pressure of 11.7 atm (SD 2.4), only 21% of stents were optimally expanded. After NCB inflation at a mean of 16.9 atm (SD 2.8), MSD increased by 0.26 mm (SD 0.24), optimal stent expansion increased from 21% to 58% and mean stent symmetry ratio increased from 0.83 to 0.87 (p < 0.0001). Conclusions Contemporary stents are sub-optimally expanded in the majority of cases after standard deployment compared with nominal sizes. Adjunctive NCB post-dilation optimized an additional 37% of stents. DSE analysis can assist in qualitative and quantitative stent assessments and can potentially facilitate a selective NCB post-dilation strategy to achieve optimal stent expansion.
منابع مشابه
Optimal Stent Expansion by Stent Balloon Multiple Inflation at Nominal Pressure in Resistant Lesions: A New Technique
Introduction: This study aimed to evaluate the effects of four-time inflation of the stent balloon at nominal pressure on optimal stent expansion in resistant lesions. Materials and Methods: This interventional study was conducted on 39 patients with coronary artery lesions, in whom Zotarolimus-eluting stents (N=20), Paclitaxel-eluting stents (N=11) and other stents (N=8) were deployed four tim...
متن کاملPilot trial of cryoplasty or conventional balloon post-dilation of nitinol stents for revascularization of peripheral arterial segments: the COBRA trial.
OBJECTIVES The purpose of this study is to compare post-dilation strategies of nitinol self-expanding stents implanted in the superficial femoral artery of diabetic patients with peripheral arterial disease. BACKGROUND Endovascular treatment of superficial femoral artery disease with nitinol self-expanding stents is associated with high rates of in-stent restenosis in patients with diabetes m...
متن کاملSafety, Efficacy and Clinical Outcome of Direct Stent Implantation
Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...
متن کاملWhat is The Next Step When a Non-Compliant Balloon Does Not Pass through a Freshly Deployed Stent?
In coronary intervention practice, optimal stent deployment in terms of adequate expansion and complete apposition is of paramount importance to obtain favorable immediate and long-term results. Even with the introduction of stent delivery systems based on a semi-compliant balloon allowing stent deployment at higher pressures (≥ 14 atm), adjunctive post dilation with a non-compliant (NC) balloo...
متن کاملStent underexpansion in angiographic guided percutaneous coronary intervention, despite adjunctive balloon post-dilatation, in drug eluting stent era
BACKGROUND Stent underexpansion is the most powerful predictor of long-term stent patency and clinical outcome. The purpose of this study was to evaluate the incidence and predictors of stent underexpansion despite adjunctive post-dilatation with non-compliant balloon. METHODS After elective coronary stent implantation and adjunctive post-dilatation with non-compliant balloon and optimal angi...