Predictability of intraocular lens calculation and early refractive status: the Infant Aphakia Treatment Study.
نویسندگان
چکیده
OBJECTIVE To report the accuracy of intraocular lens (IOL) power calculations and the early refractive status in pseudophakic eyes of infants in the Infant Aphakia Treatment Study. METHODS Eyes randomized to receive primary IOL implantation were targeted for a postoperative refraction of +8.0 diopters (D) for infants 28 to 48 days old at surgery and +6.0 D for those 49 days or older to younger than 7 months at surgery using the Holladay 1 formula. Refraction 1 month after surgery was converted to spherical equivalent, and prediction error (PE; defined as the calculated refraction minus the actual refraction) and absolute PE were calculated. Baseline eye and surgery characteristics and A-scan quality were analyzed to compare their effect on PE. MAIN OUTCOME MEASURES Prediction error. RESULTS Fifty-six eyes underwent primary IOL implantation; 7 were excluded for lack of postoperative refraction (n = 5) or incorrect technique in refraction (n = 1) or biometry (n = 1). Overall mean (SD) absolute PE was 1.8 (1.3) D and mean (SD) PE was +1.0 (2.0) D. Absolute PE was less than 1 D in 41% of eyes but greater than 2 D in 41% of eyes. Mean IOL power implanted was 29.9 D (range, 11.5-40.0 D); most eyes (88%) implanted with an IOL of 30.0 D or greater had less postoperative hyperopia than planned. Multivariate analysis revealed that only short axial length (<18 mm) was significant for higher PE. CONCLUSIONS Short axial length correlates with higher PE after IOL placement in infants. Less hyperopia than anticipated occurs with axial lengths of less than 18 mm or high-power IOLs. Application to Clinical Practice Quality A-scans are essential and higher PE is common, with a tendency for less hyperopia than expected. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT00212134.
منابع مشابه
Predictability of intraocular lens power calculation formulae in infantile eyes with unilateral congenital cataract: results from the Infant Aphakia Treatment Study.
PURPOSE To compare accuracy of intraocular lens (IOL) power calculation formulae in infantile eyes with primary IOL implantation. DESIGN Comparative case series. METHODS The Hoffer Q, Holladay 1, Holladay 2, Sanders-Retzlaff-Kraff (SRK) II, and Sanders-Retzlaff-Kraff theoretic (SRK/T) formulae were used to calculate predicted postoperative refraction for eyes that received primary IOL impla...
متن کاملThe latest generation of intraocular lenses, the problem of the eye refraction after cataract surgery.
Nowadays cataract surgery is refractive surgery as well. Intraocular lens implantation is gold standard, but there is plenty types of intraocular lenses, monofocal, multifocal, accommodating, and toric. Problem is to pick up correct one according life style, profession, health status and age. The aim is review current possibilities in cataract, refractive surgery and aphakia management.
متن کاملUnilateral Aphakia and Contact Lenses*
The size of the retinal image in the corrected aphakic eye is some 24% larger than the image before removal of the crystalline Len's. This large differential makes binocular vision impossible in individuals with unilateral aphakia corrected by spectacle lenses. A similar calculation, but with a contact lens correction, reduces this figure to about 8% (Dawson, 1962) . Theoretically, intraocular ...
متن کاملSecondary Artisan-Verysise aphakic lens implantation.
PURPOSE To evaluate efficacy, predictability and safety of Artisan-Verysise intraocular lens (IOL) secondary implantation for aphakia correction. SETTING Instituto de Microcirugía Ocular, and Autonoma University of Barcelona, Barcelona, Spain. METHODS Uncorrected visual acuity, best spectacle-corrected visual acuity (BSCVA), manifest refraction, endothelial cell count, and clinical complica...
متن کاملThree-year follow-up of secondary anterior iris fixation of an aphakic intraocular lens to correct aphakia.
PURPOSE To evaluate the efficacy, predictability, stability, safety, and complications of secondary anterior iris fixation of the Artisan iris-fixated intraocular lens (IOL) to correct aphakia in eyes without sufficient capsule support. SETTING Department of Ophthalmology, Jinling Hospital, School of Medicine, Nanjing University, Nanjing, China. DESIGN Cohort study. METHODS Eyes having im...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Archives of ophthalmology
دوره 130 3 شماره
صفحات -
تاریخ انتشار 2012