Enhancing transfusion safety with an innovative bar-code-based tracking system.
نویسندگان
چکیده
In an effort to reduce transfusion errors, a novel, comprehensive, computerized wireless bar-code-based tracking system for matching patients, blood samples and blood products was created and deployed at a major academic medical centre. With a grant from the Agency for Healthcare Research and Quality, software was developed to track scans at the times of sample collection, sample arrival in the blood bank, blood product dispensation from the blood bank and blood product administration. The system was deployed in February 2005. The system was well accepted from the outset, and the sample rejection rate due to clerical errors fell from 1.82 to 0.17%; incident reports fell by 83%. At the final blood administration step, the accumulated data as of November 2008 indicated that identification errors were being detected and prevented every 42.4 days and that the scan completion rate was stable at about 99%. Process analysis suggested that these were independent events and, thus, would be expected to coincide (and potentially produce a mis-transfusion) every 4,240 days (11.6 years) on average. We estimate that the system is 10 times safer than the manual system previously employed at our institution and may be 15-20 times safer than most systems employed in the United States.
منابع مشابه
Research on Traceability System of Food Safety Based on PDF417 Two-Dimensional Bar Code
In this paper, through the research on two-dimensional bar codes of food source tracking; a set of traceability tracking system was designed based on the two bar coding algorithm and decoding algorithms. This system could generate PDF417 code based on food production, logistics and transport, supermarket and other storage information. Consumers could identify PDF417 code through a client based ...
متن کاملTechnology for enhanced transfusion safety.
Data from reporting systems around the world document that non-infectious hazards are the leading cause of serious morbidity or mortality resulting from blood transfusion. Among these non-infectious hazards, mis-transfusion represents the most frequently observed serious hazard and occurs at an estimated rate of 1 in 14,000 transfusions. Mis-transfusion events result from "lapse errors" (slip u...
متن کاملPatient misidentifications caused by errors in standard bar code technology.
BACKGROUND Bar code technology has decreased transcription errors in many healthcare applications. However, we have found that linear bar code identification methods are not failsafe. In this study, we sought to identify the sources of bar code decoding errors that generated incorrect patient identifiers when bar codes were scanned for point-of-care glucose testing and to develop solutions to p...
متن کاملElectronic Pre-Transfusion Check at the Bedside: Experience in a University Hospital
of the guidelines Background: JSTMCT Working Party on hemovigilance and safety management of blood transfusion issued the first version of guidelines for the electronic pre-transfusion check for blood administration at the bedside [33]. The current guidelines cover issues concerning: a) Pre-transfusion check procedures at the bedside b) Requirements for the electronic pre-transfusion check at t...
متن کاملDesigning an innovative curriculum model in Iran's higher education system: A qualitative study
The purpose of this study was to design an innovative curriculum model in Iran's higher education system by using Grounded theory. The study population consisted of all experts in the field of educational planning in universities and institutes of higher education affiliated with the Ministry of Science, Research and Technology. Twenty-four of them were selected by purposive sampling method and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Healthcare quarterly
دوره 12 Spec No Patient شماره
صفحات -
تاریخ انتشار 2009