THD Mitigation in Line Currents of 6-Pulse Diode Bridge Rectifier Using the Delta-Wye Transformer as a Triplen Harmonic Filter

نویسنده

  • A. N. Arvindan
چکیده

The uncontrolled three-phase bridge rectifier has the least line current distortion among six-pulse rectifiers; however, its total harmonic distortion (THD) of 31.08% is unacceptable as per the contemporary power quality standards. This paper seeks to address the issue by elimination of triplen harmonics in the line currents by providing a deltawye transformer at the ac interface i.e. between the three-phase supply and the diode bridge rectifier. The triplen harmonics circulate in the delta loop of the primary winding but are not manifested in the line currents thus reducing their THD values. The efficacy of the technique is proved by simulations considering the bridge rectifier with and without the delta-wye transformer of vector group Dy1. Experimental results with the Dy1 transformer and without it are presented. Keywords— diode bridge rectifier, improved power quality, total harmonic distortion, triplen harmonics.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Harmonic Mitigation using 36-Pulse AC-DC Converter for Direct Torque Controlled Induction Motor Drives

This paper presents the design and analysis of a transformer based 36-pulse ac-dc converters which supplies direct torque controlled induction motor drives (DTCIMD’s) in order to have better power quality conditions at the point of common coupling. The converters output voltage is accomplished via two paralleled eighteen-pulse ac-dc converters each of them consisting of nine-phase diode bridge ...

متن کامل

Modeling and Simulation of Hybrid Electric Vehicle Power Systems

Using a top-down design methodology, two levels of hybrid electric vehicle power system are presented in the paper. At the highest abstraction level, a behavior modeling method is used to develop models for 3-phase AC/DC converter and brushless DC motor controller, which reduce the simulation time without compromise of accuracy. At the second level of design, six diodes along with delta-delta a...

متن کامل

Design of Delta Primary - Transposed zigzag Secondary (DTz) Transformer to Minimize Harmonic Currents on the Three-phase Electric Power Distribution System

The delta primary transposed zigzag secondary (DTz) transformer has been designed and used to reduce the bad impacts of the harmonic in the distribution power system. The DTz transformer is constructed with delta connection in primary winding and the three transposed windings at the different core legs of secondary winding. The harmonic reduction method of the DTz transformer applies two basic ...

متن کامل

A Novel Delta/Hexagon-Connected Transformer-Based 72-Pulse AC-DC Converter for Power Quality Improvement

Submitted: Apr 21, 2013; Accepted: Jun 4, 2013; Published: Jun 22, 2013 Abstract: This paper presents a pulse doubling technique in a 36-pulse ac-dc converter which supplies direct torque-controlled motor drives (DTCIMD’s) in order to have better power quality conditions at the point of common coupling. The proposed technique increases the number of rectification pulses without significant chan...

متن کامل

Simulation of three - phase bridge rectifier using MATLAB / SIMULINK for harmonic mitigation

Power quality standards (IEEE-519) compel to limit the total harmonic distortion (THD) within acceptable range caused by rapid usage of power electronic equipment. This paper envisages on the simulation of instantaneous active and reactive theory based shunt active filter with MATLAB/Simulink, as a better solution for reduction of the harmonics.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010