Investigation of LaBr3: Ce and LaCl3: Ce scintillators for spect imaging

نویسندگان

  • Khalid S. Alzimami
  • Nicholas M. Spyrou
  • Salem A. Sassi
چکیده

This study aims to investigate the potential use of LaBr3:Ce and LaCl3:Ce materials in SPECT imaging. GATE Monte Carlo simulations of single-head gamma camera and a Tc point source were performed to evaluate the energy spectra, modulation transfer function (MTF) and detection efficiency. A range of Ce concentrations (0.5, 5, 10 and 15)% of LaBr3:Ce and LaCl3:Ce crystals was simulated in conjunction with efficiency calculation to find optimal concentration for SPECT imaging. The MTF curves showed the excellent MTF performance of LaCl3 and LaBr3 particularly at low frequencies. The intrinsic efficiency results demonstrated the superiority of LaBr3:Ce crystals with respect to LaCl3:Ce and NaI(Tl). Results also suggest that higher Ce concentrations for both LaBr3:Ce and LaCl3:Ce crystals only slightly improve intrinsic efficiency. In conclusion, because LaCl3:Ce and LaBr3:Ce combine excellent MTF performance with increased intrinsic efficiency, they have the potential to replace NaI(Tl) as the scintillators of choice for SPECT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulse-shape discrimination of La halide scintillators

The bright scintillators LaCl3:Ce and LaBr3:Ce were tested for a–g pulse-shape discrimination (PSD). PSD is demonstrated for LaCl3:Ce but not for LaBr3:Ce: r 2005 Elsevier B.V. All rights reserved.

متن کامل

Nonproportional response of LaBr3:Ce and LaCl3:Ce scintillators to synchrotron x-ray irradiation.

The nonproportional scintillation response of LaBr(3) doped with 5% Ce(3+) and of LaCl(3) doped with 10% Ce(3+) was measured using highly monochromatic synchrotron irradiation. To estimate the photon response, pulse height spectra at many finely spaced energy values between 9 and 100 keV were measured. The experiment was carried out at the X-1 beamline at the Hamburger Synhrotronstrahlungslabor...

متن کامل

Optimization of a SPECT system for imaging of 90Y in liver using Monte Carlo method

Introduction: Acquiring a high quality image has assigned an important concern for obtaining accurate diagnosis in nuclear medicine. Detector and collimator are critical component of Single Photon Emission Computed Tomography (SPECT) imaging system for giving accurate information from exact pattern of radionuclide distribution in the target organ. The images are strongly affect...

متن کامل

Lanthanum Bromide Scintillation Detector for Gamma Spectrometry Applied in Internal Radioactive Contamination Measurements

Apariţia de noi tipuri de detectori cu scintilatori anorganici LaBr3(Ce) şi LaCl3(Ce), a generat necesitatea testării lor pentru diferite aplicaţii. Ca o alternativă a detectorului NaI(Tl), utilizat, în mod tradiţional, în sistemele gama de monitorizare a I-131, în tiroidă, a fost considerat pentru caracterizare, un detector LaBr3(Ce), de dimensiuni 1.5“ x 1.5”. Rezultatele au fost evaluate, ur...

متن کامل

Charge carrier and exciton dynamics in LaBr3:Ce scintillators: Experiment and model

The scintillation yield and decay time of LaBr3 doped with 0.2%, 0.5%, and 5% cerium were studied between 80 K and 600 K. LaBr3 :5%Ce 3+ on a photomultiplier tube shows at 300 K a very high scintillation yield of 22 800 photoelectrons per MeV 64 000 photons per MeV with a decay time of 16 ns. At 600 K the yield decreases by 15%. The scintillation yield of LaBr3 :0.2%Ce3+ is 19 800 photoelectron...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008