Implementation of Dynamic Line Rating in a Sub-Transmission System for Wind Power Integration
نویسندگان
چکیده
Based on conventional static line rating method, the actual current carrying capability of overhead conductors cannot be judged. Due to continuous increment in electricity demand and the difficulties associated with new line constructions, the overhead lines are therefore required to be rated based on a method that should establish their real-time capability in terms of electricity transmission. The method used to determine the real-time ampacity of overhead conductors not only can enhance their transmission capacity but can also help in allowing excessive renewable generation in the electricity network. In this research work, the issues related to analyzing an impact of wind power on periodical loading of overhead line as well as finding its static and dynamic ampacities with line current are investigated in detail. Moreover, the investigation related to finding a suitable location for the construction of a 60 MW wind farm is taken on board. Thereafter, the wind park is integrated with a regional grid, owned by Fortum Distribution AB. In addition to that, the electricity generated from the wind park is also calculated in this project. Later on, the work is devoted to finding the static and dynamic line ratings for “VL3” overhead conductor by using IEEE-738-2006 standard. Furthermore, the project also deals with finding the line current and making its comparison with maximum capacity of overhead conductor (VL3) for loading it in such a way that no any violation of safe ground clearance requirements is observed at all. Besides, the line current, knowing the conductor temperature when it transmits the required electricity in the presence of wind power generation is also an important factor to be taken into consideration. Therefore, based on real-time ambient conditions with actual line loading and with the help of IEEE-738-2006 standard, the conductor temperature is also calculated in this project. At the end, an economic analysis is performed to evaluate the financial advantages related to applying the dynamic line ratings approach in place of traditional static line ratings technique across an overhead conductor (VL3) and to know how much beneficial it is to temporarily postpone the rebuilding and/or construction of a new transmission line. Furthermore, an economic analysis related to Corresponding author.
منابع مشابه
Using Dynamic Thermal Rating and Energy Storage Systems Technologies Simultaneously for Optimal Integration and Utilization of Renewable Energy Sources
Nowadays, optimal integration and utilization of renewable energy sources (RES) are of the most challenging issues in power systems. The wind and solar generation units' maximum production may or may not occur at peak consumption times resulting in non-optimal utilization of these resources. As a solution to this problem, energy storage systems (ESS) are embedded in networks. However, the power...
متن کاملDynamic Stabilization of Wind Farms Deploying Static Synchronous Series Compensator
Encountering series-compensated transmission lines, sub-synchronous resonance (SSR) may strike the power system by jeopardizing its stability and mechanical facilities. This paper aims to verify the capability of static synchronous series compensator (SSSC) in mitigating the mechanical and electrical oscillations such as SSR in wind farm integrations. A wind turbine with a self–excited inductio...
متن کاملAnalyzing Impacts of FACTS Devices in Dealing with Short-Term and Long-Term Wind Turbine Faults
More than one hundred countries are using wind energy due to their easy implementation, cheap energy, and high energy efficiency. Implementation of FACTS devices in Wind Energy Conversion Systems (WECS) has been dramatically improved due to cooperative and accurate performance of FACTS devices. However, dealing with wind turbine faults promptly is crucial. Short-term and long-term faults may ha...
متن کاملImpact of Dynamic Line Rating on Dispatch Decisions and Integration of Variable RES Energy
Dynamic line rating (DLR) models the transmission capacity of overhead lines as a function of ambient conditions. It takes advantage of the physical thermal property of overhead line conductors, thus making DLR less conservative compared to the traditional worst-case oriented nominal line rating (NLR). Employing DLR brings potential benefits for grid integration of variable Renewable Energy Sou...
متن کاملCost/benefit analysis of transmission grid expansion to enable further integration of renewable electricity generation in Austria
This paper elaborates on the costs and benefits of expanding the Austrian transmission system and the implementation of innovative grid-impacting technologies (e.g. flexible AC transmission systems (FACTS), dynamic line rating (DLR)) to support further integration of renewable energy sources for electricity generation (RES-E). Therefore, a fundamental market model has been developed respecting ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -