Development of fiber optic fluorescence oxygen sensor in both in vitro and in vivo systems.

نویسندگان

  • Jinjun Jiang
  • Lei Gao
  • Wei Zhong
  • Shen Meng
  • Ben Yong
  • Yuanlin Song
  • Xiangdong Wang
  • Chunxue Bai
چکیده

The accurate measurement of arterial blood oxygen partial pressure often plays an important role in the clinical assessment of patients with respiratory conditions such as an acute exacerbation of chronic obstructive pulmonary disease and acute lung injury/adult respiratory distress syndrome. An oxygen-sensitive fluorescence indicator with high biocompatibility was synthesized and then fabricated to the end of an optical fiber. The properties and accuracy of this oxygen sensor were investigated in vitro using physiologic solutions under varying conditions or human blood, and in vivo by obtaining measurements after inserting this optical sensor into the collateral circulation system of rabbits. The sensitivity of the oxygen sensor was relatively stable during altered conditions of pH, P(CO2), osmolality, and protein concentration in solutions and during alterations of oxygen and nitrogen content in human blood. There was a linear correlation between the reciprocal value of the fluorescence intensity and Pa(O2) in both in vivo and in vitro experiments (animal arterial circulation and human blood). Our results suggest that this oxygen-sensitive fluorescence indicator, which has a high biocompatibility, may have the potential for use in real-time monitoring of blood oxygen partial pressure in various clinical settings.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A fiber optic sensor for measuring glucose in aqueous solutions

In this paper, the set-up of a multi-mode fiber optic sensor for measuring glucose in aqueous solutions is investigated and evaluated. The basis of this sensor is based on the Fresnel Reflection. In this setup, a helium-neon laser is used as a light source, a fiber optic probe, photocell as detector and a digital multimeter. The statistical analysis of the recorded data shows a highly linear be...

متن کامل

Sensitivity Enhancement of Fiber Optic Diesel Adulteration Detection Sensor Using Stripped Clad SBend Section

A novel geometry for enhancing the sensitivity of intensity modulated refractometric fiber optic sensor for detection of adulteration level in diesel by kerosene is proposed. In this multimode plastic optical fiber is uncladded for specific length and bent into S shape. This geometry is simulated and analyzed using Beam Propagation Method in Beam prop RSOFT software. When sensor is immersed in ...

متن کامل

Fiber - Optic Sensing of Linear Thermal Expansion (RESEARCH NOTES)

The use of a LED fiber-optic sensor to measure displacement and linear thermal expansion is described. It has a sensitivity of about 0.6 mV/mm, a resolution of 1.25 mm, and a dynamic rang of 400 mm for displacement measurements. For thermal expansion, it shows a sensitivity of about 3.5 mV/C, and the experimental linear expansion values are in agreement with those calculated. The reported senso...

متن کامل

Detection of singlet oxygen production for PDT treatments both in vitro and in vivo using a diode laser-based singlet oxygen monitor

Photodynamic therapy (PDT) is a promising cancer treatment. PDT uses photosensitizers that are selectively retained in malignant tumors. When tumors, pretreated with the photosensitizer, are irradiated with visible light, a photochemical reaction occurs and tumor cells are destroyed. Oxygen molecules in their metastable singlet delta state, O2(∆), are believed to be the species that destroys ca...

متن کامل

The Development of a Highly Sensitive Fiber-Optic Oxygen Sensor

Abstract: This paper presents a highly sensitive fiber-optic oxygen sensor. The sensor was fabricated using palladium (II) meso-tetrakis (pentafluorophenyl) porphyrin (PdTFPP) and porous silica nanoparticles embedded in a tetraethylorthosilane (TEOS)/n-octyl-triethoxysilane (Octyl-triEOS) composite xerogel present as a coating on the end of the fiber. Sensitivity is quantified in terms of the r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Respiratory physiology & neurobiology

دوره 161 2  شماره 

صفحات  -

تاریخ انتشار 2008