Assessment of reference values for selected elements in a healthy urban population.
نویسندگان
چکیده
Reference values for 26 elements, namely Al, Ba, Be, Bi, Ca, Cd, Co, Cr, Cu, Fe, Hg, Li, Mg, Mn, Mo, Ni, Pb, Sb, Si, Sn, Sr, Tl, V, W, Zn and Zr are proposed in serum and blood of 110 healthy adults of the urban area of Rome. They were included in the study on the basis of strict criteria of eligibility and exclusion. With the exception of Ba, Bi, Co, Cr, Ni, Sb, Sn Tl in serum, and Bi, Hg, Si, V and W in whole blood, experimental data for each all the other analytes were found to approach a normal distribution. The estimated 5-95% references ranges (in ng ml(-1)) were reported. For several elements the reference ranges observed overlapped information available in the literature. Gender, age, body mass index, smoking habits and alcohol consume were used as grouping variables. Mutual associations were observed for several elements, as follows: Be, Ca, Co, Cr, Cu, Li, Mo, Pb and Zn with sex; Ca, Pb and Si with age (< and > 45 years); Co, Cr, Mo, Sb and Tl with body mass index; Cd and Pb with smoking habit; Cr and Pb with alcohol consume.
منابع مشابه
Establishment of Reference Interval for Homeostasis Model Assessment of Insulin Resistance in Healthy Adult Males: a Pilot Study in Alexandria Governorate, Egypt
Abstract Objective: Homeostasis model assessment of insulin resistance (HOMA-IR) is a simple and practical method for estimation of insulin resistance (IR), but a reliable reference interval (RI) of HOMA-IR is needed to deduce the threshold level to define IR. This RI has been controversial in different populations and even more divergent when considering factors like age, gender and body mass...
متن کاملHematological Reference Values for Healthy Males in the Central Part of Iran
Background and Objectives: Laboratory reference values are an important tool for clinical management of patients. Reference values being used in most laboratories in Iran have been provided from the established reference values from developed countries. However, several variables can affect on these laboratory parameters. Therefore, this study was carried out to establish the reference value...
متن کاملDetermination of PTT mean value to measure INR in urban population of Khorramabad
Introduction: Coagulation disorders are among the diseases which afflict people and result in the death of a great number of them. Bleeding and increase of coagulation most of the time are endangers for many patients. The aim of this research was determination of PTT in urban population of Khorramabad. Materials & Methods: Through this study among 20-60 years old population living in Khorrama...
متن کاملEffect of height on F-wave latency: Redefining reference values for Iranian population
Intrudaction: F-wave latency is one of the most sensitive parameters which is used for diagnosis of radiculopathy and neuropathy in electrodiagnostic medicine. Electrodianosis professionals mostly use reference values published in major textbooks mostly written in USA based on anthropomorphic characteristics of American people. Also there is considerable difference between heights of males an...
متن کاملDetermination of reference ranges using medical laboratory date
In order to have reliable reference ranges and to minimize the effects of variables such as the procedure of specimen collection, geographical location, dietary habits, life style and possible errors during the performance of tests, it is recommended that each medical laboratory establish it's own reference values. Idealy, the reference ranges Should be determined by analysis of specimens from...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Annali dell'Istituto superiore di sanita
دوره 41 2 شماره
صفحات -
تاریخ انتشار 2005