An interlaboratory comparison of control materials for use with hematofluorometers.

نویسندگان

  • P J Parsons
  • N V Stanton
  • E W Gunter
  • D Huff
  • J R Meola
  • A A Reilly
چکیده

This interlaboratory study was conducted to examine four erythrocyte protoporphyrin control materials from Aviv Biomedical, Helena Laboratories, Kaulson Laboratories, and the New York State Department of Health for use with hematofluorometers. Our principal aims were to monitor the stability of these materials at three different storage temperatures (room, refrigerator, freezer) and, where appropriate, to validate the manufacturer's target values. Measurements for the study were generated in three reference laboratories that used a total of five hematofluorometers, three from Environmental Science Associates and two from Aviv Biomedical. Each instrument was calibrated against a consensus acetic acid-ethyl acetate extraction procedure. We found the materials from Aviv to be the most stable, followed by the New York State material. However, the target values assigned by Aviv were not within the acceptable range determined by consensus. The target values assigned by Kaulson Laboratories for their materials did fall within the acceptable consensus range, but they were the least stable of the materials evaluated. The materials from Helena Laboratories were originally designed for use as calibrators with Helena's "ProtoFluor Z" hematofluorometer, which reports in different units. They were deemed unsuitable for use as control materials with the Aviv or Environmental Science Associates hematofluorometers because of the narrow range of values and the wide scatter of results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Some factors affecting the utility of bovine blood as a control material in lead-screening programs.

Bovine blood is used frequently as control material in interlaboratory comparisons for blood-lead analysis, but an erythrocyte protoporphyrin control material is needed. We present data on the rate of changes in blood lead and erythrocyte protoporphyrin in steers fed lead acetate. We also show, by comparison of fluorescence spectra with those of known compounds, that most of the porphyrin in le...

متن کامل

National Association for Proficiency Testing

These suggestions are as follows: 1) Regular use of certified reference materials and/or internal quality control using secondary reference materials 2) Participation in interlaboratory comparison or proficiency testing programs 3) Replicate tests or calibrations using the same or different methods 4) Retesting or recalibration of retained items 5) Correlation of results for different character...

متن کامل

Quality control in haematology: report of interlaboratory trials in Britain.

An interlaboratory quality control scheme has been established in Britain by the British Committee for Standards in Haematology. In the first instance this has been confined to haemoglobin, red blood cell count, and packed cell volume. The materials which have been circulated include whole blood, stabilized red cell preparations, lysates, cyanmethaemoglobin solutions, and cyanmethaemoglobin ref...

متن کامل

Determination of perfluorinated alkyl acid concentrations in human serum and milk standard reference materials.

Standard Reference Materials (SRMs) are certified reference materials produced by the National Institute of Standards and Technology that are homogeneous materials well characterized with values for specified properties, such as environmental contaminant concentrations. They can be used to validate measurement methods and are critical in improving data quality. Disagreements in perfluorinated a...

متن کامل

Certification of standard reference material 970, ascorbic acid in serum, and analysis of associated interlaboratory bias in the measurement process.

BACKGROUND The accurate and reproducible measurement of ascorbic acid is essential in delineating the role of ascorbic acid as a diagnostic tool for human disease and for the comparison of data acquired by different laboratories. A stabilized pair of standards of ascorbic acid in human serum, which is compatible with most analytical methods, have been prepared. METHODS The certification was b...