Frequency-doubling technology perimetry and optical defocus.
نویسندگان
چکیده
PURPOSE The frequency-doubling technology (FDT) perimeter has no provision for introducing corrective lenses, save for the patient's spectacles, and so patients are sometimes tested in the presence of moderate levels of defocus. The effect of defocus on frequency-doubling (FD) sensitivity was determined for both the commercially available instrument and for smaller targets that may be useful in spatially localizing visual field defects. In addition, whether stimulus artifacts may be detectable in the presence of defocus was assessed. METHODS Detection and resolution thresholds for FD stimuli, along with detection thresholds for spatially uniform flickering stimuli, were measured in normal observers in the presence of up to +6 D of defocus. In addition, the effect of defocus on the summary indices (mean deviation [MD], and pattern standard deviation [PSD]) of both the commercial FDT perimeter and a customized perimeter with smaller, higher spatial frequency targets was determined. RESULTS Thresholds for conventional FD targets (0.25 cyc/deg, 25 Hz) increased 0.1 log unit with +6 D defocus, whereas thresholds for smaller, higher spatial frequency (0.5 cyc/deg) targets increased 0.4 log unit. Despite the presence of a luminance artifact in the FD stimuli, detection, and resolution thresholds remained coincident at maximum defocus, suggesting that the artifact was not detectable. MD was significantly affected by defocus for the customized FD perimeter only, and PSD was not altered for either the conventional or customized test. CONCLUSIONS In normal observers, optical defocus has little effect on FDT perimetry sensitivity and does not make low spatial frequency artifacts detectable. Improving the spatial resolution of FDT perimetry decreases its robustness to defocus.
منابع مشابه
[Agreement and correlation between the frequency doubling perimetry and the blue-yellow perimetry in glaucoma: no support for selective damage].
PURPOSE To test the agreement and correlation between the frequency doubling technology and the short wavelength perimetry in glaucoma. METHODS Glaucoma patients were selected from the Glaucoma Sector of CEROF - Universidade Federal de Goiás, and then underwent frequency doubling technology and short wavelength perimetry examinations in both eyes (if eligible) on the same day in a random sequ...
متن کاملFrequency doubling technology perimetry for detection of glaucomatous visual field loss.
PURPOSE To evaluate the ability of frequency doubling technology perimetry to detect early, moderate, and advanced glaucomatous visual field loss. METHODS In a prospective study, frequency doubling technology perimetry (C-20 full threshold) was performed in the right eye of 254 normal control subjects and 230 patients with early (n = 85), moderate (n = 114), or advanced (n = 31) glaucomatous ...
متن کاملFrequency Doubling Perimetry
DOS Times Vol. 11, No. 6 December, 2005 The goal of perimetry is to establish an accurate estimate of visual field sensitivity. Perimetry is performed to detect early visual field defects, determine specific patterns of visual field loss for differential diagnosis and monitor for evidence of progression of field loss. Conventionally Standard Achromatic Perimetry (SAP) has been used to achieve t...
متن کاملScreening for glaucoma with frequency-doubling technology and Damato campimetry.
OBJECTIVE To assess frequency-doubling technology (FDT) perimetry (Humphrey Systems, San Leandro, Calif) and Damato campimetry (Precision Vision, Villa Park, Ill) for detecting glaucoma in a public glaucoma screening. METHODS A 2-day public glaucoma screening was held at 2 different institutions. Each subject underwent 2 visual field screening tests (Damato campimetry and FDT perimetry in scr...
متن کاملClinical comparison of frequency doubling technology perimetry and Humphrey perimetry.
AIM To determine the number of missed points on frequency doubling technology (FDT) perimetry that optimise the sensitivity and specificity of the test and to determine the topographical accuracy of the test in a clinical setting. METHODS In a prospective study, the perimetric data from 99 patients who underwent both FDT perimetry in the screening mode and Humphrey 24-2 (H24-2) were used to d...