CDI Blood Parameter Monitoring System 500--a new tool for the clinical perfusionist.
نویسندگان
چکیده
Sarns/3M Health Care has recently introduced the CDI 500 Blood Parameter Monitoring System. In addition to parameters previously available, this system now offers continuous monitoring of the patient's oxygen consumption (VO2/min) and potassium concentration ([K+]). The purpose of this study was: (1) to compare the [K+] from the CDI 500 with the [K+] derived from our hospital's laboratory; and (2) to compare the VO2/min from the CDI 500 with the results obtained utilizing the "gold-standard" Fick equation. The mean absolute difference in [K+] was 0.10 mEq/L with a mean percentage error of only 3.93%. The mean absolute difference in VO2/min was 18.78 ml O2/min, with a mean percentage error of 11.63%. We concluded that the [K+] correlated well and that 9.13% of the oxygen consumption percentage error was attributable to the exclusion of dissolved oxygen in the calculation used by the CDI 500, with the remaining 2.5% attributable to differences in technology. We recommended that future upgrades to the CDI 500 should include dissolved O2 when measuring oxygen consumption and consideration should be given to increasing the operating range for [K+].
منابع مشابه
Use of the CDI blood parameter monitoring system 500 for continuous blood gas measurement during extracorporeal membrane oxygenation simulation.
UNLABELLED The Oximetrix III Opticath (Abbott Critical Care Systems) is used for continuous measurement of venous saturation in a variety of applications, including extracorporeal membrane oxygenation (ECMO), despite clinical reports that have presented data showing poor accuracy of these devices. The CDI Blood Parameter Monitoring System 500 (Terumo) is an inline blood gas monitoring tool comm...
متن کاملImproving cardiopulmonary bypass: does continuous blood gas monitoring have a role to play?
The CDI 500 (Terumo Cardiovascular Systems, Ann Arbor, MI) is an in-line blood gas monitoring device that has been used in clinical practice for over a decade. Few randomized studies have evaluated the value of this device with respect to improved perfusion management. We routinely use automated continuous quality indicator programs to assess perfusion management. The aim of this study is to in...
متن کاملClinical evaluation of a new in-line continuous blood gas monitor.
Two methodologies for obtaining accurate blood gas and electrolyte values during cardiopulmonary bypass (CPB) are traditional laboratory analyzers, which use an electrochemical technology, and continuous in-line monitoring systems, which use a fluorometric and/or spectrophotometric technology. The purpose of the present study was to evaluate the accuracy of a new continuous in-line monitor, the...
متن کاملClinical evaluation of the CDI-100 in-line hematocrit/saturation monitor.
This study was undertaken to evaluate the accuracy, reliability, consistency and biases of the CDI-100 saturation monitor when compared with a blood gas analyzer. The advantage of continuous in-line monitoring is that the perfusionist has continuous updates as to the patient's changing physiologic state. During this study, if the sample readout of the CDI-100 was off by greater than 10% from th...
متن کاملGelsomino 1 Assessment of a Continuous Blood Gas Monitoring System in Animals during Circulatory stress. Short Title: Continuous Blood Gas Monitoring
Introduction: The study was aimed to determine the measurement accuracy of The CDI TM blood parameter monitoring system 500 (Terumo Cardiovascular Systems Corporation, Ann Arbor MI) in the real-time continuous measurement of arterial blood gases under different cardiocirculatory stress conditions Methods: Inotropic stimulation (Dobutamine 2.5 and 5 μg/kg/min), vasoconstriction (Argininevasopres...