Frequency band of EMG in anaesthesia monitoring.

نویسندگان

  • K Kamata
  • A J Aho
  • S Hagihira
  • A Yli-Hankala
  • V Jäntti
چکیده

undergoing abdominal surgery. After animal use committee approval, 14 pigs were anaesthetized and the tracheas intubated with appropriately sized Hi-Lo Evac (n1⁄47) or TaperGuard Evac (n1⁄47) tracheal tubes. Saline based-fluid (pH 2.5/0.3 ml kg) stained with Methylene-Blue was instilled into the area below the vocal cords but above the inflated tracheal tube cuff via the Evac port. The cuff pressure was measured every 15 min and maintained between 25 and 30 mm H2O for both tracheal tubes using a Posey cufflator (Posey Health Care Products, Arcadia, CA, USA). The lungs were ventilated to achieve normocarbia and each pig underwent abdominal surgery. At the end of surgery, the pigs were killed by lethal injection and the tracheal tubes were left in place with the cuffs inflated until the autopsy. At autopsy, a gross visual assessment was made of dye distribution into the trachea and lungs. Gross and histological examination of large, intermediate, and small airway mucosa and pulmonary parenchyma was performed to assess for inflammatory changes related to aspiration. However, one pig in the TaperGuard group had to be excluded due to accidental cuff deflation. The incidence of microaspiration was significantly less for TaperGuard in the dye leak and bronchitis groups (Table 1). As a result of the dye leak from the accidental cuff deflation, the difference in the other two categories did not reach statistical significance but may be clinically significant. We suggest further animal and clinical studies to confirm our results and impressions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Facial muscle activity, Response Entropy, and State Entropy indices during noxious stimuli in propofol–nitrous oxide or propofol–nitrous oxide–remifentanil anaesthesia without neuromuscular block

BACKGROUND Entropy is an anaesthetic EEG monitoring method, calculating two numerical parameters: State Entropy (SE, range 0-91) and Response Entropy (RE, range 0-100). Low Entropy numbers indicate unconsciousness. SE uses the frequency range 0.8-32 Hz, representing predominantly the EEG activity. RE is calculated at 0.8-47 Hz, consisting of both EEG and facial EMG. RE-SE difference (RE-SE) can...

متن کامل

Acoustic monitoring of intraoperative neuromuscular block.

Standard methods for accurate intraoperative measurement of neuromuscular block are either expensive or inconvenient and are not used widely. We have evaluated a new method of monitoring neuromuscular block using a low-frequency microphone. The method is based on the phenomenon of low-frequency sound emission by contracting skeletal muscle. Acoustic monitoring (MIC) with an air-coupled micropho...

متن کامل

A Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia

Background: The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may not provide clear heart and lung sound due to existence of various noises in operating rooms. In addition, the stethoscope is not applicable for continues monitoring, and it is u...

متن کامل

Effect of sugammadex or neostigmine neuromuscular block reversal on bispectral index monitoring of propofol/remifentanil anaesthesia.

BACKGROUND Sugammadex is a modified γ-cyclodextrin with a novel mechanism of action for reversing the steroidal neuromuscular blocking agent rocuronium. Bispectral index (BIS) is an EEG-derived measure which can be sensitive to frontal electromyographic (EMG) artifacts. We compared BIS values before and after sugammadex or neostigmine neuromuscular block (NMB) reversal in patients with or witho...

متن کامل

Physical activity is a major contributor to the ultra low frequency components of heart rate variability.

OBJECTIVE To investigate the link between changes in level of physical activity and the pattern of heart rate variability during long term ambulatory monitoring. DESIGN Heart rate variability was measured simultaneously with a quantitative indicator of muscle activity by electromyography (EMG) in five men and five women while they did activities typical of daily life or while they rested for ...

متن کامل

Restrict relaxants, be aware, and know the limitations of your depth of anaesthesia monitor.

In this issue of the British Journal of Anaesthesia, Schuller and colleagues examined the effect of neuromuscular block on the EEG bispectral index (BIS) in awake subjects. The researchers induced the scenario of awakeparalysis in consenting volunteers. Recent data indicate that awake paralysis is one of the main factors for distress during awareness, and may be even more critical than experien...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 107 5  شماره 

صفحات  -

تاریخ انتشار 2011