The Effect of Torque Application Technique on Screw Preload of Implant-Supported Prostheses.
نویسندگان
چکیده
PURPOSE To examine the effect of different torque application techniques (torqued, retorqued once, and retorqued twice) on the removal torque of implant-supported fixed complete dental prostheses. MATERIALS AND METHODS Four Nobel Biocare implants (4.3 × 13 + 3; 13-mm thread height + 3-mm collar height) were stabilized temporarily inside four holes made in an acrylic mandibular master model. A metal framework was constructed, casted, and finished using a standardized technique. A passively fitting framework was achieved by removing the implants from the acrylic master model and hand-screwing them to the metal framework. Then, the whole assembly was restabilized in the acrylic master model. The torque experiment consisted of three protocols: (1) torquing screws to 35 Ncm a single time; (2) torquing the screws to 35 Ncm and then immediately retorquing the same screws to the same value; and (3) torquing the same screws to 35 Ncm three consecutive times. Removal torque was recorded for each implant using a digital torque meter. RESULTS The highest torque value was recorded for the retorqued-once application technique (29.5 ± 1.5 Ncm); next was the torqued technique (27.9 ± 0.7 Ncm); and, last was the retorqued-twice technique (27.2 ± 1.6 Ncm). The Games-Howell post hoc test showed that the retorqued-once application technique resulted in significantly higher torque values than the torqued and retorqued-twice torque application techniques (P ≤ .05). CONCLUSION Retightening abutment screws once after the initial torquing could enhance the removal torque of the screw. Care must be taken when retorquing the screws more than once, as this may inversely affect the removal torque.
منابع مشابه
A comparison of preload values in gold and titanium dental implant retaining screws.
This in vitro investigation compared the effect of using either gold or titanium retaining screws on preload in the dental implant- abutment complex. Inadequate preload can result in screw loosening, whilst fracture may occur if preload is excessive. These are the most commonly reported complications in implant-retained prostheses, and result in unscheduled, costly and time-consuming visits for...
متن کاملEffect of Misfit on Preload Maintenance of Retention Screws of Implant-Supported Prostheses
The aim of this study was to evaluate the effect of unilateral misfit at different levels on a crown-implantretention screw system of implant-supported crowns. Hexagon castable UCLA abutments were cast in Co-Cr alloy to fabricate 48 metallic crowns divided into four groups (n = 12). Group A: crowns did not present misfit; Groups B, C and D: crowns were fabricated with unilateral misfit of 50, 1...
متن کاملEffect of Vertical Misfit on Screw Joint Stability of Implant-Supported Crowns
The passive fit between prosthesis and implant is a relevant factor for screw joint stability and treatment success. The aim of this study was to evaluate the influence of vertical misfit in abutment-implant interface on preload maintenance of retention screw of implant-supported crowns. The crowns were fabricated with different abutments and veneering materials and divided into 5 groups (n = 1...
متن کاملPreload and Torque Removal Evaluation of Three Different Abutment Screws for Single Standing Implant Restorations
Several authors still consider the mechanical problems of fracture and component loosening as the main causes of failure of implant-supported restorations. The purpose of this in vitro study was to compare the preload of three types of screw for transmucosal abutment attachment used in single implant-supported prosthesis through strain gauge and removal torque measurements. Three external hex f...
متن کاملIn Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening
Preload is applied to screws manually or using a torque wrench in dental implant systems, and the preload applied must be appropriate for the purpose. The aim of this study was to assess screw loosening and bending/torsional moments applied by clinicians of various specialties following application of manual tightening torque to combinations of implants and abutments. Ten-millimeter implants of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The International journal of oral & maxillofacial implants
دوره 32 2 شماره
صفحات -
تاریخ انتشار 2017