Specimen holders for simultaneous critical point drying of multiple biological specimens.

نویسندگان

  • R M Rice
  • A F Hegyeli
  • L G Breeden
چکیده

Specimen holders were developed for simultaneous critical point drying of multiple specimens of monolayer cell cultures grown on Leighton tube glass cover slips or for specimens of cells collected on silver or cellulose membrane filters. The use of these multiple specimen holders makes it possible to process several specimens in parallel and thus significantly reduce the time required for handling large numbers of samples and also eliminate the possible variations that occur in processing individual samples one at a time in series.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Soft-tissue specimen shrinkage during the preparation for scanning electron microscopy

The amount of shrinkage and the scanning electron microscope appearance of specimens of rat tongue, soft palate and small intestine, dehydrated by air­ drying, the critical point technique, the camphene technique and freeze drying were compared. In the specimens of tongue the area shrinkage ranged be­ tween 11,8 and 30,4 per cent, in the soft palate from 19,8 to 37,4 per cent and in the small i...

متن کامل

Freeze-drying of Biological Specimens for Electron Microscopy Using Thermoelectric Cooling

Freeze-drying for electron microscopy is one of the most successful methods for avoiding specimen distortion caused by drying of liquid solutions in air. It has been calculated that the surface forces of receding droplets subject small specimens to pressures of the order of tons per square inch (1). In freeze-drying, an aqueous solution of the specimen is rapidly frozen and the ice allowed to s...

متن کامل

Low-temperature Scanning Electron Microscopy of Frozen Hydrated Apple Tissues and Surface Organisms

Frozen hydrated buds and epicarp of ‘Golden Delicious’ apple (Malus domestica Borkh.) were observed with a low-temperature, field emission scanning electron microscope (SEM). In addition to observing surface features of these specimens, holders were modified to observe fractured specimens. A modified hinged holder retained both halves of a fractured specimen for examination of the complementary...

متن کامل

Fractographic Studies of Plastic-embedded Cells by Scanning Electron Microscopy

Three-dimensional views of cell structures at high magnifications made possible by the scanning electron microscope (SEM) are becoming increasingly useful to biologists. Methods that have proved useful for stabilizing biological soft tissue for observation in the SEM include the critical point method (1, 2), freeze drying, freeze fracturing followed by freeze drying (4, 9, 10), observation of s...

متن کامل

Microtrabecular lattice of the cytoplasmic ground substance. Artifact or reality

The cytoplasmic ground substance of cultured cells prepared for high voltage transmission electron microscopy (glutaraldehyde/osmium fixed, alcohol or acetone dehydrated, critical-point dried) consists of slender (3-6 nm Diam) strands--the microtrabeculae (55)--that form an irregular three-dimensional lattice (the microtrabecular lattice). The microtrabeculae interconnect the membranous and non...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stain technology

دوره 51 1  شماره 

صفحات  -

تاریخ انتشار 1976