Spectral Profile Design for Multiple Repetition Time Balanced SSFP

نویسندگان

  • R. R. Ingle
  • T. Çukur
  • D. G. Nishimura
چکیده

Introduction: Balanced SSFP (bSSFP) enables rapid image acquisition with high SNR but elicits an undesirable bright fat signal. Several steady-state sequence designs permit varying degrees of spectral shaping, allowing the fat signal to be suppressed by designing a stopband centered around the lipid resonant frequency [1-3]. Previous work on multiple repetition time (multi-TR) bSSFP has often relied on hand-selection and tuning of a large number of free parameters to achieve sequences with broad stopbands and uniform passbands. In general, the automatic selection of parameters for a desired spectral profile is a difficult non-convex optimization problem. In this work, we propose a method for optimizing a given multi-TR bSSFP sequence to yield an improved spectral profile, such as an increased passband-to-stopband ratio. Methods: To optimize the spectral profile of a given steady-state sequence, a linear model of magnetization versus flip angle is constructed and used to compute the flip angles that minimize the squared error with a desired spectral profile. The reference sequence and its profile serve as an initialization point for the linearization technique. Various sets of RF flip angles are perturbed, and a linear model is constructed relating changes in flip angles to changes in spectral profile. To create a passband at the water resonant frequency (0 Hz), the transverse magnetization must be nonzero, which requires the sequence of excitations during a single period to result in no net excitation. Neglecting relaxation, the flip angles (αj) and RF phases (φj) of a multi-TR bSSFP sequence with N excitations per period should be constrained by α1exp(iφ1)+...+αNexp(iφN)=0. The manner in which the flip-angles are perturbed must satisfy this constraint, otherwise a sharp null can occur at 0 Hz. This method is demonstrated on a reference multi-TR bSSFP sequence [1] with four 60° RF pulses with alternating 0°-180° phases, TR1=TR2=3.45 ms, and TR3=TR4=1.725 ms (Fig. 1). Bloch simulation shows that small perturbations of the RF flip angles result in approximately linear changes in the profile (Fig. 2). For 0°-180° phase cycling, the flip angle constraint reduces to α1-α2+α3-α4=0, and pairs of flip angles with opposite RF phases, i.e., (α1,α2), (α3,α4), (α1,α4), and (α2,α3), can be perturbed without violating the constraint. Least-squares analysis is used to compute the four flip angles that yield the best fit to a desired magnetization profile of 0 in the stopband (-470 Hz to -110 Hz) and a constant value in the passband (-50 Hz to 50 Hz). The optimization procedure results in a new flip angle sequence of α=(89, 114, 89, 64)°. Both sequences are simulated using T1/T2 = 1000/200 ms for arterial blood, and the resulting normalized profiles are shown in Fig. 3. The designed sequence has a superior passband-to-stopband ratio of 13 dB in comparison to 7 dB for the reference sequence. The improvement in stopband attenuation comes at the expense of a slightly less uniform passband and higher SAR due to increased flip angles. Results: Spectral profiles of the reference and designed sequences were acquired by imaging a phantom with a linear gradient shim, resulting in a vertically-varying precession frequency (Fig. 4). Images were acquired on a 1.5 T GE scanner with a 24x24 cm FOV, 0.9 mm in-plane resolution, 5 mm slice thickness, and a readout bandwidth of ±62.5 kHz. Profiles taken from a central cross-section of the reference and designed images are plotted in Fig. 5. Both measured profiles agree closely with the simulated profiles shown in Fig. 3. The passband-to-stopband ratio of the designed sequence is improved by 6 dB, in agreement with the simulation results. The notches in the center of the passband are the result of relaxation and other phase effects. This phenomenon is denoted “central signal dip” and is explained in greater detail in [4]. Conclusions: A method for optimizing the spectral profile of a given multi-TR bSSFP sequence has been proposed and analyzed via Bloch simulations and phantom imaging. The technique resulted in significant improvement in stopband attenuation. Future work includes investigation of a similar technique based on perturbations of TRs and RF phases. Figure 1. Diagram of one period of a 2-2-1-1 multi-TR SSFP sequence. TR1=TR2=3.45 ms, TR3=TR4=1.725 ms. RF phase = (0°,180°,0°,180°). Flip angle = (α1, α2, α3, α4).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wideband SSFP: alternating repetition time balanced steady state free precession with increased band spacing.

Balanced steady-state free precession (SSFP) imaging is limited by off-resonance banding artifacts, which occur with periodicity 1/TR in the frequency spectrum. A novel balanced SSFP technique for widening the band spacing in the frequency response is described. This method, called wideband SSFP, utilizes two alternating repetition times with alternating RF phase, and maintains high SNR and T(2...

متن کامل

Improved 3-Tesla cardiac cine imaging using wideband.

Cine balanced steady-state free precession (SSFP) is the most widely used sequence for assessing cardiac ventricular function at 1.5 T because it provides high signal-to-noise ratio efficiency and strong contrast between myocardium and blood. At 3 T, the use of SSFP is limited by susceptibility-induced off-resonance, resulting in either banding artifacts or the need to use a short-sequence puls...

متن کامل

Use of Simulated Annealing for the Design of Multiple TR bSSFP Sequences in Positive Contrast Imaging

Introduction With low flip angles, the balanced steady-state free precession (bSSFP) spectral profile shows a broad minimum on resonance, and sharp off-resonance maxima. The FLAPS (Fast Low Angle balanced steady-state free Precession) method [1] exploits this to generate positive contrast with low SAR from susceptibility-induced field variations, e.g. from superparamagnetic iron oxide particles...

متن کامل

Time Optimal VERSE Excitation for 3D Balanced SSFP Imaging

Figure 3. Coronal (top) and axial (bottom) views from a 3D acquisiton slightly above the heart. Images have 2x2x3 mm resolution. The coronal image shows the 4cm, TB=10 slab profile in vivo. The contrast is consistent across the slab, indicating a flat slab profile. The black level is 0 for these images. Introduction: Balanced steady-state free precession (SSFP) imaging (TrueFISP, FIESTA, balanc...

متن کامل

Diffusion Effects in Passband Balanced SSFP fMRI

Introduction Changes in resonance frequency caused by varying deoxyhemoglobin concentrations are the basis of blood oxygenation level dependent (BOLD) MR imaging (1). In functional brain studies mostly T2*-weighted sequences are used to detect BOLD signal levels. It has been shown that also balanced steady-state free precession (bSSFP) imaging sequences may be employed to measure deoxyhemoglobi...

متن کامل