Clinical comparisons of continuous venous oxygen saturation and hematocrit monitors in pediatric surgery.

نویسندگان

  • D Bennett
  • J Burnside
  • J Langwell
  • P D Beckley
چکیده

Continuous venous oxygen saturation and hematocrit values are important parameters in assessing patient status while on cardiopulmonary bypass. Two devices used to measure continuous venous oxygen saturation while on cardiopulmonary bypass were compared to a control. The Bentley Oxysat meter and the Medtronic MX2 Oxygen Saturation and Hematocrit System were compared to the ABL500 blood gas monitor. The continuous hematocrit readings from the MX2 system were compared to spun hematocrits. Twenty-nine pediatric patients ranging from 2.3kg-43.3kg were randomly selected. In-line optical transmission cells used were 1/4" or 3/8" depending upon the patient's blood flow requirements. A total of 163 data points were analyzed at different blood flow rates, temperatures, and hematocrits. The venous oxygen saturation values obtained from the Oxysat and the MX2 devices correlated well with the ABL500 over the entire range of blood flows, temperatures, and hematocrits. All correlation coefficients were greater than 0.89. The correlation between the MX2 device and the spun hematocrit varied with temperature ranges. The correlation coefficient tended to decrease with decreasing temperature. We conclude that these devices are important adjuncts to bypass as long as their limitations are understood.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro evaluation of continuous mixed venous oxygen saturation and hematocrit monitors.

Four venous hemoglobin oxygen saturation monitors, two of which provide hemoglobin monitoring, were evaluated and compared to a performance standard (control) during cardiopulmonary bypass (CPB). The CDI 100 Hematocrit/Saturation Monitor, CDI 400, Cobe Hematocrit/Saturation Monitor, and the Baxter Bentley OxySat values were compared to the Radiometer Copenhagen OSM3 Hemoximeter and the Damon In...

متن کامل

Continuous venous oximetry: a comparative study between the CDI 100 and the Bentley OxySat II.

Two in-line oxygen saturation monitors, the CDI 100 and OxySat II, were evaluated in the clinical setting. Eighty-seven venous blood samples were drawn during 20 elective cardiopulmonary bypass procedures. Monitor readings were compared to OSM III co-oximeter values. The results revealed that saturation (%) determination was biased, -3.16 +/- 2.21 SD for the CDI 100 and -0.34 +/- 2.17 SD for th...

متن کامل

Central venous oxygen saturation and blood lactate levels during cardiopulmonary bypass are associated with outcome after pediatric cardiac surgery

INTRODUCTION Central venous oxygen saturation and blood lactate are different indices of the adequacy of oxygen delivery to the oxygen needs. In pediatric cardiac surgery, lactate level and kinetics during and after cardiopulmonary bypass are associated with outcome variables. The aim of this study was to explore the hypothesis that the lowest central venous oxygen saturation and the peak lacta...

متن کامل

Regional and central venous oxygen saturation monitoring following pediatric cardiac surgery: concordance and association with clinical variables.

OBJECTIVE To compare changes in regional cerebral or flank oxygen saturation measured by near-infrared spectroscopy with changes in central venous oxygen saturation (ScvO2) and to determine clinical variables associated with these changes. DESIGN Prospective observational cohort study. SETTING University tertiary care center, pediatric cardiac intensive care unit. PATIENTS Seventy postope...

متن کامل

Accuracy of in-line venous saturation and hematocrit monitors in pediatric perfusion.

Cardiopulmonary bypass (CPB) in neonates and infants routinely employs lower blood flow rates (BFR), temperatures, and hematocrits (Hct) than those typically observed in adult CPB. The purpose of this study was to evaluate the accuracy of three devices available for continuous in-line measurement of venous oxygen saturation (SvO2) and Hct during pediatric CPB. Venous blood samples were obtained...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 25 4  شماره 

صفحات  -

تاریخ انتشار 1993