Electrosurgery in patients with implantable electronic cardiac devices (pacemakers and defibrillators).

نویسندگان

  • B García Bracamonte
  • J Rodriguez
  • R Casado
  • F Vanaclocha
چکیده

The electrosurgical unit is a very useful tool widely used in dermatology to treat benign and malignant skin lesions and to achieve hemostasis during surgery. However, precautions are required when this technique is used in patients with implantable electronic cardiac devices (IECD), such as pacemakers and defibrillators, because electromagnetic interference produced by the tool may cause such devices to malfunction. Before using electrosurgery in patients with IECDs, it is essential to ascertain the type of implanted device and the patient's level of dependence on it. The location of the skin lesion to be treated with respect to the device should also be assessed. Bipolar pacemakers are more resistant to interference. Appropriate monitoring and the use of bipolar forceps are recommended.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrosurgery and implantable electronic devices: review and implications for office-based procedures.

The number of patients with implantable electronic devices (IEDs) is growing as indications for a myriad of cardiac and neurological disorders that cannot be managed using medication alone expand. These devices include gastric and cardiac pacemakers, implantable cardioverter defibrillators, cochlear implants, and a range of stimulators of the deep brain, vagal nerve, sacral nerve, phrenic nerve...

متن کامل

Erosive Pressure Dermatitis Associated with Cardiac Pacemaker

Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor fo...

متن کامل

Safety of magnetic resonance imaging in patients with implanted cardiac prostheses and metallic cardiovascular electronic devices.

Magnetic resonance imaging (MRI) in patients with implanted cardiac prostheses and metallic cardiovascular electronic devices is sometimes a risky procedure. Thus MRI in these patients should be performed when it is the only examination able to help with the diagnosis. Moreover the diagnostic benefit must outweigh the risks. Coronary artery stents, prosthetic cardiac valves, metal sternal sutur...

متن کامل

Endoscopy and implantable electronic devices.

The increasing use of implantable electronic devices such as cardiac pacemakers and neurostimulators means that they are being increasingly encountered in endoscopy departments. The electromagnetic fields generated during electrosurgery and with magnetic imaging systems have the potential to interfere with such devices. The authors present a case that highlights some of the steps necessary for ...

متن کامل

Anaesthetic consideration in patients with cardiac implantable electronic devices scheduled for surgery

With advances in cardiology and cardiothoracic surgery, several newer implantable cardiac devices have become common in the surgical population. Multichamber pacemakers, implanted cardiac defibrillators and ventricular assist devices are frequent in current day practice. Many of the newer implantable cardiac electronic devices are targeted at managing heart failure. While managing such patients...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Actas dermo-sifiliograficas

دوره 104 2  شماره 

صفحات  -

تاریخ انتشار 2013