Comparison of three auto-adjusting positive pressure devices in patients with sleep apnoea.

نویسندگان

  • G M Nolan
  • S Ryan
  • T M O'connor
  • W T McNicholas
چکیده

Auto-adjustable continuous positive airway pressure (APAP) devices are an emerging treatment alternative to fixed-pressure continuous positive airway pressure (CPAP) therapy for obstructive sleep apnoea syndrome. They have been engineered to automatically adjust the pressure to the optimal level on a continuous basis. However, not all APAP technologies use the same algorithm. Three different APAP devices (Autoset Spirit, Breas PV 10i and RemStar Auto) were compared in a randomised crossover trial in patients already established on fixed-pressure CPAP therapy. The outcome measures were compliance, quality of life and side-effects. Twenty-seven middle-aged patients (25 male) previously diagnosed with severe obstructive sleep apnoea syndrome (median (interquartile range) apnoea/hypopnoea index 48 (29-76)), established on CPAP therapy for >3 yrs, were randomised to each APAP device for 4 weeks. Mean pressure and patient compliance were significantly lower on the Breas PV 10i than on the other APAP devices. The devices were similar in terms of quality of life, daytime sleepiness and upper airway side-effects, but patients evaluated them significantly differently in terms of device features, sleep quality and pressure comfort, with the Breas PV 10i being the least popular. Auto-adjustable positive airway pressure devices differ in pressure delivery and patient compliance in obstructive sleep apnoea syndrome patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Importance of sleep stage- and body position-dependence of sleep apnoea in determining benefits to auto-CPAP therapy.

The influence of sleep stage- and body position-dependence of sleep apnoea on treatment efficacy and compliance between conventional continuous positive airway pressure (CPAP) and auto CPAP therapy was evaluated. Thirty-three newly treated sleep apnoea hypopnoea syndrome (SAHS) patients were randomly allocated to conventional or auto-CPAP therapy. Six patients of each treatment group were class...

متن کامل

Auto-adjusting versus fixed positive pressure therapy in mild to moderate obstructive sleep apnoea.

STUDY OBJECTIVES To determine if auto-adjusting positive airway pressure (APAP) would be better tolerated on the basis of delivering a lower mean pressure in patients with mild to moderate obstructive sleep apnoea syndrome (OSAS). DESIGN Patients spent 8 weeks on continuous positive airway pressure (CPAP) and 8 weeks on APAP in a randomized crossover design. SETTING Respiratory Sleep Disord...

متن کامل

Evaluation of an auto-nCPAP device based on snoring detection.

We evaluated an auto-nasal continuous positive airway pressure (nCPAP) prototype (MC+; SEFAM, Nancy, France) in which apnoea/hypopnoea detection was disabled and nasal mask pressure vibration detection was the only mode of pressure setting. The device was tested in 15 previously untreated obstructive sleep apnoea patients during a night with polysomnography. We observed that a single night of a...

متن کامل

Two months follow up of auto-CPAP treatment in patients with obstructive sleep apnoea.

BACKGROUND Continuous positive airway pressure (CPAP) with fixed mask pressure is the current standard treatment for obstructive sleep apnoea (OSA). Auto-CPAP devices apply at any time the minimally required pressure to normalise breathing and may improve patient comfort and compliance. We present an open descriptive study of auto-CPAP treatment at home in patients previously managed with conve...

متن کامل

Snoring detection during auto-nasal continuous positive airway pressure.

A bench study using an artificial lung model was performed to evaluate the snoring detection sensitivity of six (commercially available) auto-nasal continuous positive airway pressure (NCPAP) devices. Snoring was simulated by a loudspeaker connected to the lung model and abruptly activated during 1 s of each inspiratory period to induce pressure oscillation. The oscillation frequencies chosen w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The European respiratory journal

دوره 28 1  شماره 

صفحات  -

تاریخ انتشار 2006