ENDURALIFE-Powered Cardiac Resynchronisation Therapy Defibrillator Devices for Treating Heart Failure: A NICE Medical Technology Guidance
نویسندگان
چکیده
ENDURALIFE™-powered cardiac resynchronisation therapy defibrillator (CRT-D) devices were the subject of an evaluation by the National Institute for Health and Care Excellence, through its Medical Technologies Evaluation Programme, for the treatment of heart failure. Boston Scientific (manufacturer) submitted a case for the adoption of the technology, claiming that it has a longer battery life resulting in a longer time to CRT-D replacement. Other claimed benefits were fewer complications associated with replacement procedures, fewer hospital admissions, less time spent in hospital and reduced demand on cardiology device implantation rooms. The submission was critiqued by Cedar, an external assessment centre. The submitted clinical evidence showed that ENDURALIFE-powered devices implanted during the period 2008-2010 were superior, in terms of longevity, to other devices at that time. Submitted economic evidence indicated that, because of a reduction in the need for replacement procedures, ENDURALIFE-powered devices were cost saving when compared to comparator devices. Cedar highlighted uncertainty of the applicability of the clinical evidence to devices marketed today. The Medical Technologies Advisory Committee noted that this was unavoidable due to the follow-up time required to study battery life. Clinical experts noted that increased battery life is an important patient benefit. However, centres use devices from multiple manufacturers to negate pressure on clinical services in the event of a major device recall. The clinical and economic evidence showed benefits to the patient, and further analysis requested by the committee suggested that ENDURALIFE-powered CRT-Ds may save between £2120 and £5627 per patient over 15 years through a reduction in the need for replacement procedures. ENDURALIFE-powered CRT-D devices received a positive recommendation in Medical Technologies Guidance 33.
منابع مشابه
Cardiac resynchronisation therapy for the treatment of heart failure: NICE technology appraisal guidance.
This NICE technology appraisal guidance on cardiac resynchronisation therapy provides additional treatment options for some of the groups of people covered in the earlier guidance on implantable cardioverter defibrillators.
متن کاملOverview of implantable cardioverter defibrillator and cardiac resynchronisation therapy in heart failure management.
Clinical trials have established the benefits of implantable cardioverter defibrillators (ICDs) and cardiac resynchronisation therapy (CRT) in the treatment of heart failure patients. As adjuncts to guideline-directed medical therapy, ICDs confer mortality benefits from sudden cardiac arrest, while CRT reduces mortality, hospitalisation rates and improves functional capacity. This review discus...
متن کاملCombined resynchronisation and implantable defibrillator therapy in left ventricular dysfunction: Bayesian network meta-analysis of randomised controlled trials.
OBJECTIVE To review the evidence base from randomised controlled trials of combined cardiac resynchronisation therapy and implantable cardioverter defibrillator therapy in left ventricular impairment and symptomatic heart failure. DESIGN Bayesian network meta-analysis. DATA SOURCES Medline, Embase, and Cochrane databases up to June 2006. REVIEW METHODS Two reviewers independently assessed...
متن کاملManagement of Cardiac Electronic Device Infections: Challenges and Outcomes.
Cardiac implantable electronic device (CIED) infection is an increasing problem. Reasons for this are uncertain, but likely relate to an increasing proportion of implantable cardioverter defibrillator (ICD) and cardiac resynchronisation therapy (CRT) devices implanted, as well as implantations in 'higher risk' candidates, i.e. patients with heart failure, diabetes and renal failure. Challenges ...
متن کاملEffect of cardiac resynchronisation therapy on occurrence of ventricular arrhythmia in patients with implantable cardioverter defibrillators undergoing upgrade to cardiac resynchronisation therapy devices.
BACKGROUND Cardiac resynchronisation therapy (CRT) improves outcomes in selected patients with heart failure and left ventricular dysfunction. One mechanism of benefit is believed to be favourable ventricular remodelling. Whether CRT also decreases the frequency of ventricular arrhythmias and risk of sudden death is unknown. OBJECTIVE To determine the effect of CRT on frequency of ventricular...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -
تاریخ انتشار 2018