Soft tissue response to zirconia and titanium implant abutments: an in vivo within-subject comparison.

نویسندگان

  • Ralph van Brakel
  • Gert J Meijer
  • Jan Willem Verhoeven
  • John Jansen
  • Cornelis de Putter
  • Marco S Cune
چکیده

AIM To compare the health of the soft tissues towards zirconia and titanium abutments in man, as observed using histological data. MATERIAL AND METHODS Twenty patients received two mandibular implants with either a zirconia or titanium abutment (split mouth study design, left-right randomization). After 3 months soft tissue biopsies were prepared for histological evaluation. They were subjected to blind evaluation. The number of blood vessels per surface unit and an inflammation grading scale score ranging from 1 to 4 were determined. RESULTS Paired samples from 17 patients were suitable for analysis, 3 with unsevered implant-abutment connections and 14 solely containing soft tissue. All showed a well-keratinized stratified squamous epithelium which was continuous with the barrier (junctional) epithelium that faced the abutment surface. The normal epithelial build-up could be recognized with little signs of inflammation. No statistically significant difference in tissues adjacent to zirconia and titanium abutment surfaces were seen with respect to vascular density (20.5 SD 4.4 and 20.7 SD 3.2) or inflammation grading scale scores (3.2 SD 0.7 versus 3.1 SD 0.7). CONCLUSION No differences in soft tissue health were seen in peri-implant mucosa adjacent to zirconia and titanium abutment surfaces.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of the peri-implant soft tissues in contact with zirconia abutments: an evidence-based literature review.

AIM The aim of this study is to evaluate through a literature review, the soft tissue response in contact with zirconia abutments, including case reports comparing prosthetics rehabilitations with zirconia and titanium abutments upto 3 years of follow-up as well as the factors that should be considered on implant's abutment selection. BACKGROUND Metallic abutments can provide grayish color wh...

متن کامل

Comparative Evaluation of Microleakage at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study

Abstract Background and aim: Oral microbiota could proliferate the microspace between the implant and abutment, thereby cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microleakage at implant-abutment interface area under oblique cyclic loading in vitro. Materials and methods:In thi...

متن کامل

Evaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro

Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...

متن کامل

A Clinical Study Assessing the Influence of Anodized Titanium and Zirconium Dioxide Abutments and Peri-implant Soft Tissue Thickness on the Optical Outcome of Implant-Supported Lithium Disilicate Single Crowns.

PURPOSE To assess the influence of anodized titanium and zirconium dioxide abutments and peri-implant soft tissue thickness on the optical outcome of implant-supported lithium disilicate single crowns. MATERIALS AND METHODS Twenty patients with a missing maxillary single incisor, canine, or first premolar received an endosseous implant after a two-stage surgery protocol. After healing and sof...

متن کامل

Comparative Evaluation of Microgap at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study

Abstract   Background and Aim : Microgap in the implant-abutment interface is one of the main challenges in the treatment of two-piece implants. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microgap at implant-abutment interface area under oblique cyclic loading in vitro. Methods and Materials In this in vitro study, 12 implant-abutment assemb...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical periodontology

دوره 39 10  شماره 

صفحات  -

تاریخ انتشار 2012