Dependence of TIMP-1 plasma levels on preanalytical specimen handling.

نویسندگان

  • Marie Dresse
  • Dorothea Nagel
  • Eva-Maria Ganser
  • Gerard Davis
  • Barry Dowell
  • Robert Doss
  • Petra Stieber
چکیده

BACKGROUND Tissue inhibitor of metalloproteinases-1 (TIMP-1) in blood might be a helpful biomarker in various diseases. However, various authors report that TIMP-1 is dependent on preanalytical procedures. Our study was performed to determine how storage conditions and time to centrifugation influence TIMP-1. MATERIALS AND METHODS Twenty-six blood specimens were collected from each of 20 volunteers. Two specimens from each person were centrifuged/measured within 1 h after venipuncture and frozen at -80 degrees C. They were thawed once or twice within 72 h. Eight specimens were stored at 20 degrees C in daylight, 8 at 20 degrees C covered and 8 at 4 degrees C in daylight. Four of each of these 8 specimens were mixed once a day until centrifugation. A mixed and an unmixed specimen of each group was centrifuged/measured after 3, 6, 24 and 72 h. RESULTS TIMP-1 increased after freeze/thaw (p < 0.001). Mixing blood specimens more than once caused increased TIMP-1 (p < 0.001). TIMP-1 increased within 3 h of storage (p < 0.001). The increase was lower in specimens covered and refrigerated (p < 0.001). CONCLUSION TIMP-1 is unstable and has to be evaluated carefully. Blood should be centrifuged directly after venipuncture. For routine application, specimen handling must be standardized and carefully followed. Research should be done on specimens handled identically.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of collection tube type and preanalytical handling on myeloperoxidase concentrations.

BACKGROUND Myeloperoxidase (MPO) has shown potential as a marker for cardiovascular disease. Limited studies have been published with a variety of sample types, resulting in a wide range of MPO values. Little is known or understood about the impact of collection tube type and preanalytical handling of specimens for MPO determination. METHOD MPO concentration was determined by use of the ARCHI...

متن کامل

Matrix metalloproteinases do not properly work as peripheral blood biomarkers without taking into account the preanalytical impact of blood sampling.

I read with great interest the article by Aharinejad et al. [1]. The authors measured matrix metalloproteinases (MMP) 1, 8, and 9 and tissue inhibitor of metalloproteases 1 (TIMP-1) in the serum of heart transplant recipients during the first year after cardiac transplantation at different time intervals. The changed serum concentrations of these analytes following cardiac transplantation were ...

متن کامل

Correlation of Plasma MMP-1 and TIMP-1 Levels and the Colonic Mucosa Expressions in Patients with Ulcerative Colitis

BACKGROUND Both plasma and mucosal levels of matrix metalloproteinase-1 (MMP-1) and tissue inhibitor of metalloproteinase-1 (TIMP-1) have been shown to be independently correlated with ulcerative colitis (UC), but their relationship with each other and to disease severity remains unclear. This study aims to evaluate the relationship between colonic mucosal and plasma levels of MMP-1 and TIMP-1 ...

متن کامل

Estimation of Preanalytical Uncertainty in Clinical Chemistry

Preanalytical uncertainty is attributable to variations in blood sample collection and sample handling before analysis. The aim of this study was to establish a modelling framework for estimating preanalytical uncertainty. There is a need for standardization on which uncertainty sources that should be included, and how the preanalytical uncertainty should be estimated. In Paper I, an uncertaint...

متن کامل

Evaluation of the Du Pont Axial Separation system.

We evaluated the Du Pont Axial Separation Technology (AST) system, which permanently separates a blood specimen into serum or plasma and cells in 1 min. Blood was collected in axial processing containers by standard venipuncture techniques and processed in an Axial Separation Module. Paired patient samples (n = 48 serum pairs, n = 50 plasma pairs) revealed no clinically significant differences ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Tumour biology : the journal of the International Society for Oncodevelopmental Biology and Medicine

دوره 29 1  شماره 

صفحات  -

تاریخ انتشار 2008